Liquid Controls SP2900 User Manual

Page 10

background image

SETTING

16 POINT

K-FACTOR

16 POINT

ONLY

APPEARS
ON UNITS

WITH

16 POINT

OPTION

PRESS

DISPLAY

MENU FLASHES TO DEV TYP

LOCKOUT

OUTCARD

ALG OUT

OUT FREQ

RELAY

16 POINT

(16 POINT SELECTED)

MINUTES

HOURS

TEST

SECONDS

(PRESS D TO GO TO MINUTES)

(PRESS AS DESIRED)

POINT 00 (ENTER POINT 00 TO GO TO RUN
MODE)

(SELECT POINT 1)

POINT 01 (KEY IN POINT DESIRED)

F ## (SHOWS FREQUENCY IN MEMORY)

F 0

(AS AN EXAMPLE)

F 100 (FREQUENCY FOR POINT 1 IS 100)

K ## (SHOWS K-FACTOR IN MEMORY)

K 0

(AS AN EXAMPLE)

100 (K-FACTOR FOR POINT 1 IS 100)

POINT 02 (ENTER POINT DATA AS DESIRED)

POINT 00 (ENTER POINT 00 TO EXIT SETUP)

LAST COUNT READING

D

D

D

D

D

D

D

ENT

D

D

D

ENT

1

ENT

CLR

1

0

0

ENT

CLR

1

0

0

ENT

CLR

ENT

NOTE: If TEST
is entered, point
data can be
entered exactly
as in selected
time entries.
However, when
the unit "runs"
in Test Mode
"K-factor is
always 1.
"Rate" (R)
displays
frequency
(inputs per
second).
Counter dis-
plays 1 count
per each input.

NOTE: "BAD
SEQ" will
appear if
frquencies are
not in ascend-
ing order with
point numbers.
After 2 sec-
onds, the first
point number
with error will
appear so data
can be viewed
and corrected.

8