beautypg.com

Ab c d, Application, Features – Liquid Controls SP2900 User Manual

Page 3: Description

background image

PRE A

PRE B

RATE/TOTAL MENU

A

B

C

D

1

2

3

5

4

6

8

7

9

0

ENT

CLR

APPLICATION

Batch control, cut to length, packaging, blending. The
display may be toggled between total, rate, and grand total.
Programmable K-factor makes keying - in engineering units
easy. Unit accepts pulse, contact closures or analog input
and provides two separate preset controls.

FEATURES

* Pulse or Analog Input (with Totalizing
Integration)
* Display Total, Rate or Grand Total
* 2 Presets - User Selectable for Total, Rate or
Grand Total
* Pulse Input to 20 KHz Count Frequency
* 16 Point Linearization
* K - Factor Programmable to 8 Places
* Security Lockout
* 2 way RS232/422/422M Communications
* NEMA 4X Front Panel
* Scaleable 4 - 20mA Output of Rate
* Scaled Pulse Out, Frequency Selectable

DESCRIPTION

Featuring 8 digits of bright, .55”, alphanumeric display, the
pulse input version of the unit can accept up to 20,000
pulses per second. The analog input version accepts
inputs, such as 4 to 20mA or 1 to 5V. It uses a highly linear
integrator (V to F converter) to generate 0 to 10KHz digital
pulses. The unit has two separate, 8 digit, floating decimal,
“K” factors to convert the inputs to meaningful count and
rate data. The user, with the push of a button, can toggle
back and forth to view the total of the batch, the rate of flow
and the grand total count.

Two controls outputs can be assigned independently by the
user to activate at preset batch count, rate or grand total for
.1 to 9.9 seconds or until reset externally.

A scaled pulse output is also provided by an open collector
driver. Since the output frequency is user selectable at 10,
200, 2K or 20KHz, the unit can transmit the count data to
electromechanical or electronic counters as well as com-
puters, programmable controllers or other monitor equip-
ment.

An optional analog 4 to 20mA output, selectable between
rate or total, allows the user to select 4mA and 20mA rate
settings to control strip chart recorders or other peripherals.

Up to 15 units can be connected to optional RS232 or
RS422 communications port to set control points or access
data. With RS422M up to 256 units can be linked together
and addressed separately to transmit unit states or accept
new set points. The Baud rate is “Auto Ranging” from 300
to 19.2K. It is also OPTOMUX Compatible.

PRE A

PRE B

RATE/TOTAL MENU

A

B

C

D

1

2

3

5

4

6

8

7

9

0

ENT

CLR

PRE A

PRE B

RATE/TOTAL MENU

A

B

C

D

1

2

3

5

4

6

8

7

9

0

ENT

CLR

PRESS "C" TO SEE RATE

PRESS "C" AGAIN TO SEE
BATCH TOTAL.

PRESS "ENT" TO SEE

GRAND TOTAL

1