beautypg.com

Inputs/outputs digital input – Liquid Controls HML210 IOM - LCMag User Manual

Page 12

background image


HML 210

12

The functions referring to the inputs could be divided in three groups:

1) only assignable functions to the input 1
2) functions that act directly on the inputs independently from the select input
3) only assignable functions to the input 1 and only to the input 2 which interact

between them


For details see the following pages.

Remember that the activation of any functions of batch automatically disable the other.
The list of such functions is suitable in the table of the batch function configuration
section.

INPUTS/OUTPUTS

DIGITAL INPUT





































3-40VDC (ON)
0-1.5VDC (OFF)

5 (+)

6 (-)

10k

5

6

20

0

15

+24

10k

External power supply

Internal power supply