1. ORDERING GUIDE
Configure a model number in this format: L20201DCV1, CBL01
L…….Digital panel meter with
screw terminal connectors.
Display Color
1...............DPM with green LED
2.................. DPM with red LED
3..... Extended DPM, green LED
4........ Extended DPM, red LED
Note: Extended adds rate of
change & linearization of non-
linear inputs. Not applicable to
thermocouple or RTD inputs.
Power
0............................. 85-264 Vac
1.......... 10-48 Vdc or 12-32 Vac
Setpoint Output
0....................................... None
1.............Two 8A contact relays
2..............Two solid state relays
3............ Four 8A contact relays
4............. Four solid state relays
Analog Output
0....................................... None
1...... 4-20 mA, 0-10V, -10/+10V
Digital Interface
0....................................... None
1.....................................RS232
2.....................................RS485
4....................... RS485-Modbus
5........................................ USB
6.........USB-to-RS485 converter
7.................................. Ethernet
8.. Ethernet-to-RS485 converter
Input Type
DC Volts
DCV1 ...................... 200.00 mV
DCV2 ......................... 2.0000 V
DCV3 ......................... 20.000 V
DCV4 ......................... 200.00 V
DCV5*.......................... 600.0 V
DCV6 ........................... 300.0 V
DC Amperes
DCA1 .................... 2.0000 mA
DCA2 .................... 20.000 mA
DCA3 .................... 200.00 mA
DCA4 ......................... 5.000 A
RTDs
P385C ... Pt100, -202 to 850°C
P385F .. Pt100, -331 to 1562°F
P392C. .. Pt100, -202 to 850°C
P392F .. Pt100, -331 to 1562°F
N672C..... Ni120, -80 to 260°C
N672F ....Ni120, -112 to 500°F
C427C.... Cu10, -202 to 850°C
C427F ...Cu10, -331 to 1562°F
Thermocouples
JC .....................-210 to 760°C
JF.................... -347 to 1400°F
KC...................-244 to 1372°C
KF ................... -408 to 2501°F
TC .....................-257 to 400°C
TF ..................... -430 to 752°F
EC ...................-240 to 1000°C
EF ................... -400 to 1830°F
NC...................-245 to 1300°C
NF ................... -410 to 2370°F
SC .....................-46 to 1768°C
SF ..................... -51 to 3214°F
RC.....................-45 to 1768°C
RF ..................... -49 to 3213°F
Resistance / Ohms
R1 ................... 0-20.000 ohms
R2 ................... 0-200.00 ohms
R3 ................. 0-2.0000 kohms
R4 ................. 0-20.000 kohms
R5 ................. 0-200.00 kohms
R6 .... 0-2 Mohms (fixed range)
Process Signals
(4-20 mA, 0-10V, etc.)
P ............. 4-20 mA = 0-100.00
P1…………….Custom Scaling
Specify min signal & reading,
max signal & reading.
*
Range not ETL approved
.
Strain Gauge, Potentiometer
(4-wire ratio)
SG......... 0-200 mV = 0-100.00
SG1................Custom Scaling
Specify min signal & reading,
max signal & reading. Full-
scale ranges 200 mV to 20V.
RMS Volts
RMV1 .................... 200.00 mV
RMV2 ....................... 2.0000 V
RMV3 ....................... 20.000 V
RMV4 ....................... 200.00 V
RMV5*........................ 600.0 V
RMV6 ......................... 300.0 V
RMS Amperes
RMA1 .................... 2.0000 mA
RMA2 .................... 20.000 mA
RMA3 .................... 200.00 mA
RMA4 ......................... 5.000 A
Load Cells (6-wire ratio)
WM1….…..-99,999 to +99,999
Specify min input signal & dis-
played reading, and max input
signal & displayed reading.
Full-scale inputs 20 mV to 500
mV. 10 Vdc excitation.
Options & Accessories
BL .........Blank lens, no button
pads
.
CBL01...RJ11-to-DB9 RS232
cable. Connects me-
ter to PC com port.
CBL02...USB-to-DB9 adapter.
For use with CBL01.
CBL05...USB-cable. Type A
male to Type B male.
IPC ........NEMA-4 panel cover.
BOX1 ....NEMA4 wall mount
enclosure.