Press Menu
Select Key
Press Digit
Select Key
Press Value Select
Key
000_0
Operation as a rate of
change meter.
Extended meter only.
0
Not rate of change
1
Rate x 0.1
2
Rate x 1
3
Rate x 10
4
Rate x 100
5
Rate x 1000
6
Rate x 10000
000_0
Operation of front
panel PEAK button
and rear connector for
Peak or Valley Display
0
Peak Display. Also selects “Peak” in
“Peak or Valley” at connector above.
1
Valley Display. Also selects “Valley” in
“Peak or Valley” at connector above.
2
Peak (1st push), Valley (2nd push)
3
Front panel Tare
000_0
Auto-tare
0
Meter comes up in normal run mode.
1
Meter comes up in auto-tare mode
ConFG
Meter Configuration
000_ 0
Nonlinear input scaling
Extended meter only.
0
Linear input
1
Custom curve linearization
00000
Alarm filtering
0
Unfiltered output
1
Filtered output
00000
Peak & Valley filtering
0
Unfiltered Peak & Valley
1
Filtered Peak & Valley
00000
Display filtering
0
Display batch average every 16 readings
1
Display filtered signal
00000
Adaptive filter
threshold
0
Low adaptive filter threshold level
1
High adaptive filter threshold level
FiLtr
Filtering
00000
Input signal filtering.
Can be applied to dis-
play, setpoint, analog
output, data output.
0
Autofilter
1
Batch average, 16 readings
2
Moving average, 0.08 sec.
3
Moving average, 0.15 sec.
4
Moving average, 0.3 sec.
5
Moving average, 0.6 sec.
6
Moving average, 1.2 sec.
7
Moving average, 2.4 sec.
8
Moving average, 4.8 sec.
9
Moving average, 9.6 sec.
A
Unfiltered
dEc.Pt
Dec. point selection
d
.
dddd
Decimal point flashes.
d
.
dddd dd
.
ddd ddd
.
dd dddd
.
d ddddd
.
.
ddddd
Press to shift the decimal point.