Configuration
CTI Products, Inc.
Program
14
68-11707-100
Standby Remote EXB Port Number
(Informational. Always port 1 for Analog (Telco) EXBs.
For Serial EXBs, this indicates which port is being used on this link.)
5.2 Critical Custom Data
This data is the system-specific data for each of the EXB modules. It tells the
EXB Network Management Software the appropriate addresses for each EXB
module.
This data must be entered exactly as specified in the
Customer Specific Package shipped by CTI Products.
Main Near Router Subnet & Node
(Hex)
Address for MCN Network side of internal router in Central Main EXB
Main Far Router Subnet & Node
(Hex)
Address for WAN side of internal router in Central Main EXB
Main Control Subnet & Node
(Hex)
Address for Control Neuron (Control processor) in Central Main EXB
Main Remote Near Router Subnet & Node (Hex)
Address for WAN side of internal router in Main Remote EXB
Main Remote Far Router Subnet & Node
(Hex)
Address for MCN Network side of internal router in Main Remote EXB
Main Control Subnet & Node
(Hex)
Address for Control Neuron (Control processor) in Main Remote EXB
Standby Near Router Subnet & Node
(Hex)
Address for MCN Network side of internal router in Central Standby EXB
Standby Far Router Subnet & Node
(Hex)
Address for WAN side of internal router in Central Standby EXB
Standby Control Subnet & Node
(Hex)
Address for Control Neuron (Control processor) in Central Standby EXB
Standby Remote Near Router Subnet & Node
(Hex)
Address for WAN side of internal router in Standby Remote EXB
Standby Remote Far Router Subnet & Node (Hex)
Address for MCN Network side of internal router in Standby Remote EXB
Standby Control Subnet & Node
(Hex)
Address for Control Neuron (Control processor) in Standby Remote EXB