CONTREX CX-1102 User Manual
Page 22

Page 20
NOTE: All Digital Outputs are activated via the PLC and so are subject to the active PLC program.
Unwind Enable
(J2 pin 2)
The Unwind Enable output is activated (driven low) when the CX-1102 signals a run command to the motor
drive. The Unwind Enable output is driven high (relay deactivated) after Power Up and at the completion of
F-Stop. See Figure 29.
Wind Enable
(J2 pin 3)
The Wind Enable output is activated (driven low) when the CX-1102 signals a run command to the motor
drive. The Wind Enable output is driven high (relay deactivated) after Power Up and at the completion of
F-Stop. See Figure 29.
Unwind Error
(J2 pin 4)
The Unwind Error output is activated (driven low) when UwndRR Err (MP-22) is greater than
E200 RPM.
See Figure 29.
Wind Error
(J2 pin 5)
The Wind Error output is activated (driven low) when WindRR Err (MP-32) is greater than
E200 RPM. See
Figure 29.
Wind Roll Full
(J2 pin 6)
The Wind Roll Full output is activated (driven low) when WindEstDia (MP-17) is greater than or equal to 72
(Diameter EU). See Figure 29.
Dancer
(J2 pin 7)
The Dancer output is activated (driven low) when the dancer content is greater than or equal to 95% of
DncrCtntFull (CP-272) or less than or equal to 5% of DncrCtntFull (CP-272). See Figure 29.