beautypg.com

Outputs, Unwind control output, Wind control output – CONTREX CX-1102 User Manual

Page 21

background image

Page 19

OUTPUTS

NOTE: The installation of this motor control must conform to area and local electrical codes. Refer to page

9 before you begin wiring.

Unwind Control Output

(J8 pins 1, 2)

Unwind Control Output is an isolated analog output
signal that is sent to the motor drive to control the
speed of the motor. Wire the Unwind Control Output
into the speed signal input of the drive. If the motor
drive has a potentiometer speed control, remove the
potentiometer connections and wire the Unwind
Control Output to the potentiometer wiper point. The
CX-1102's Isolated Common should always be
connected to the drive common.

Figure 27 Unwind Control Output

*

Do not connect the Drive Isolated Common to other Logic Commons.

1

2

J8

Unwind Control Out

Isolated Com

*

UNWIND MOTOR DRIVE

SIGNAL INPUT

DRIVE COMMON

SigU

ComU

Wind Control Output

(J3 pins 1, 2)

Wind Control Output is an isolated analog output
signal that is sent to the motor drive to control the
speed of the motor. Wire the Wind Control Output
into the speed signal input of the drive. If the motor
drive has a potentiometer speed control, remove the
potentiometer connections and wire the Wind Control
Output to the potentiometer wiper point. The CX-
1102's Isolated Common should always be connected
to the drive common.

Figure 28 Wind Control Output

*

Do not connect the Drive Isolated Common to other Logic Commons.

1

2

J3

Wind Control Out

Isolated Com

*

WIND MOTOR DRIVE

SIGNAL INPUT

DRIVE COMMON

SigW

ComW