Outputs, Unwind control output, Wind control output – CONTREX CX-1102 User Manual
Page 21

Page 19
OUTPUTS
NOTE: The installation of this motor control must conform to area and local electrical codes. Refer to page
9 before you begin wiring.
Unwind Control Output
(J8 pins 1, 2)
Unwind Control Output is an isolated analog output
signal that is sent to the motor drive to control the
speed of the motor. Wire the Unwind Control Output
into the speed signal input of the drive. If the motor
drive has a potentiometer speed control, remove the
potentiometer connections and wire the Unwind
Control Output to the potentiometer wiper point. The
CX-1102's Isolated Common should always be
connected to the drive common.
Figure 27 Unwind Control Output
*
Do not connect the Drive Isolated Common to other Logic Commons.
1
2
J8
Unwind Control Out
Isolated Com
*
UNWIND MOTOR DRIVE
SIGNAL INPUT
DRIVE COMMON
SigU
ComU
Wind Control Output
(J3 pins 1, 2)
Wind Control Output is an isolated analog output
signal that is sent to the motor drive to control the
speed of the motor. Wire the Wind Control Output
into the speed signal input of the drive. If the motor
drive has a potentiometer speed control, remove the
potentiometer connections and wire the Wind Control
Output to the potentiometer wiper point. The CX-
1102's Isolated Common should always be connected
to the drive common.
Figure 28 Wind Control Output
*
Do not connect the Drive Isolated Common to other Logic Commons.
1
2
J3
Wind Control Out
Isolated Com
*
WIND MOTOR DRIVE
SIGNAL INPUT
DRIVE COMMON
SigW
ComW