beautypg.com

Unwind jog reverse, Wind jog forward, Wind jog reverse – CONTREX CX-1102 User Manual

Page 18

background image

Page 16

Unwind Jog Reverse

(J7 pins 2, 3)

Unwind Jog Reverse is a maintained input. When it is
closed, it sends a reverse unwind control output signal
to the drive at the selected Jog Setpoint. As a
maintained input, Unwind Jog Reverse is only active
when the operator device is closed.

NOTE: Close the H-Stop, Unload and F-Stop inputs

prior to entering the Jog state. If you are only
using one of the Stop inputs, wire short the
other Stop inputs to the common or the
CX-1102 will not enter Jog.

Wind Jog Forward

(J7 pins 4, 3)

Wind Jog Forward is a maintained input. When it is
closed, it sends a forward wind control output signal to
the drive at the selected Jog Setpoint. As a maintained
input, Wind Jog Forward is only active when the
operator device is closed.

NOTE: Close the H-Stop, Unload and F-Stop inputs

prior to entering the Jog state. If you are only
using one of the Stop inputs, wire short the
other Stop inputs to the common or the
CX-1102 will not enter Jog.

Wind Jog Reverse

(J7 pins 2, 3)

Wind Jog Reverse is a maintained input. When it is
closed, it sends a reverse wind control output signal to
the drive at the selected Jog Setpoint. As a maintained
input, Wind Jog Reverse is only active when the
operator device is closed.

NOTE: Close the H-Stop, Unload and F-Stop inputs

prior to entering the Jog state. If you are only
using one of the Stop inputs, wire short the
other Stop inputs to the common or the
CX-1102 will not enter Jog.

Figure 18 Unwind Jog Reverse

UNWIND JOG REVERSE

2

3

J7

UJogR

Com

Figure 20 Wind Jog Reverse

WIND JOG REVERSE

3

5

J7

Com

WJogR

Figure 19 Wind Jog Forward

WIND JOG FORWARD

3

4

J7

Com

WJogF