Unwind jog reverse, Wind jog forward, Wind jog reverse – CONTREX CX-1102 User Manual
Page 18
![background image](/manuals/334423/18/background.png)
Page 16
Unwind Jog Reverse
(J7 pins 2, 3)
Unwind Jog Reverse is a maintained input. When it is
closed, it sends a reverse unwind control output signal
to the drive at the selected Jog Setpoint. As a
maintained input, Unwind Jog Reverse is only active
when the operator device is closed.
NOTE: Close the H-Stop, Unload and F-Stop inputs
prior to entering the Jog state. If you are only
using one of the Stop inputs, wire short the
other Stop inputs to the common or the
CX-1102 will not enter Jog.
Wind Jog Forward
(J7 pins 4, 3)
Wind Jog Forward is a maintained input. When it is
closed, it sends a forward wind control output signal to
the drive at the selected Jog Setpoint. As a maintained
input, Wind Jog Forward is only active when the
operator device is closed.
NOTE: Close the H-Stop, Unload and F-Stop inputs
prior to entering the Jog state. If you are only
using one of the Stop inputs, wire short the
other Stop inputs to the common or the
CX-1102 will not enter Jog.
Wind Jog Reverse
(J7 pins 2, 3)
Wind Jog Reverse is a maintained input. When it is
closed, it sends a reverse wind control output signal to
the drive at the selected Jog Setpoint. As a maintained
input, Wind Jog Reverse is only active when the
operator device is closed.
NOTE: Close the H-Stop, Unload and F-Stop inputs
prior to entering the Jog state. If you are only
using one of the Stop inputs, wire short the
other Stop inputs to the common or the
CX-1102 will not enter Jog.
Figure 18 Unwind Jog Reverse
UNWIND JOG REVERSE
2
3
J7
UJogR
Com
Figure 20 Wind Jog Reverse
WIND JOG REVERSE
3
5
J7
Com
WJogR
Figure 19 Wind Jog Forward
WIND JOG FORWARD
3
4
J7
Com
WJogF