Page 13
F-Stop
(J6 pins 1,3)
F-Stop is a momentary input. When it is opened, the
CX-1102 commands a zero speed immediately and
ignores the specified deceleration rate. However,
F-Stop does not hold zero speed or position (drive
disabled). As a momentary input, F-Stop is internally
latched and does not need to be maintained open by an
operator device.
Unload
(J6 pins 2, 3)
When the Unload input (J6, pin 2) is momentarily
opened, the CX-1102 enters the Unload state. As a
momentary input, Unload is internally latched and does
not need to be maintained open by an operator device.
H-Stop
(J6 pins 4, 3)
H-Stop is a momentary input. When it is opened, the
CX-1102 ramps to a zero speed command at the
specified deceleration rate. In addition, H-Stop holds
zero speed after the deceleration ramp has been
completed (drive enabled). As a momentary input,
H-Stop is internally latched and does not need to be
maintained open by an operator device.