Keypad lockout, Setup, Unwind jog forward – CONTREX CX-1102 User Manual
Page 17

Page 15
Keypad Lockout
(J6 pins 9, 8)
When the KEYPAD LOCKOUT input is closed, the
Control Parameters that you have selected to "lockout"
are inaccessible from the front keypad. All of the
Monitor Parameters remain enabled.
The Keypad Lockout input is temporally used during
the system setup procedure to initiate tests for the CX-
1102 system setup procedure.
Setup
(J6 pins 10, 8)
Setup is a maintained input. It is used only during the
system setup procedure to put the CX-1102 into “Setup
State”.
Unwind Jog Forward
(J7 pins 1, 3)
Unwind Jog Forward is a maintained input. When it is
closed, it sends a forward unwind control output signal
to the drive at the selected Jog Setpoint. As a
maintained input, Unwind Jog Forward is only active
when the operator device is closed.
NOTE: Close the H-Stop, Unload and F-Stop inputs
prior to entering the Jog state. If you are only
using one of the Stop inputs, wire short the
other Stop inputs to the common or the
CX-1102 will not enter Jog.
Figure 15 Keypad Lockout
ENABLE
8
9
J6
Com
KeyLk
LOCKOUT
Figure 16 Setup
SETUP
8
10
J6
Com
Setup
Figure 17 Unwind Jog Forward
UNWIND JOG FORWARD
1
3
J7
UJogF
Com