Sensor Input/Relay Output

z

Sensor Input connection

Before connecting sensors, check driving voltage and output signal type of the sensor. Since output signal
types of the sensors are divided into Open Collector and Voltage Output type in general, the cabling must be
done properly after considering these typed.

Signal

Description

IN COM+

Connect (+) cable of electric power source for Sensors to this port as
shown in the circuit above.

IN1-, IN2-, IN3-, IN4-

Connect output of sensors for each port as shown in the circuit above.

If you want to use Alarm Input, the types of sensor must be selected in OSD menu. The sensor types are Normal
Open and Normal. If sensor type is not selected properly, the alarm can be activated reversely.

Normal Open

Output Voltage is high state when sensor is activated

Normal Close

Output Voltage is high state when sensor is not activated

z

Relay output connection

Maximum allowable electrical load of relay is shown bellow table.

Driving Power

DC

110VAC

Max. Load

24VDC, 1A

125VAC, 0.5A

2. INSTALLATION

2. INSTALLATION

Xpeed Mini Outdoor Speed Dome Camera Series

www.cnbtec.com

18

Check points before operation

z

Before power is applied, please check the cables carefully.

z

The camera ID of the controller must be identical to that of the target camera. The camera ID can be
checked by reading DIP switch of the camera.

z

If your controller supports multi-protocols, the protocol must be changed to match to that of the camera.

z

If you changed camera protocol by changing DIP switch, the change will be effective after you reboot the
camera.

z

Since the operation method can be different for each controller available, refer to the manual for your

controller if camera can not be controlled properly. The operation of this manual is based on the standard

Pelco

®

Controller.

Preset and Pattern Function Pre-Check

z

Check how to operate preset and pattern function with controller or DVR in advance to operate camera

function fully when using controller or DVR.

z

Refer to the following table when using standard Pelco® protocol controller.

Input [Preset Number] and press [Preset] button shortly.

Input [Preset Number] and press [Preset] button for more than 2 seconds.

Input [Pattern Number] and press [Pattern] button shortly.

Input [Pattern Number] and press [Pattern] button for more than 2 seconds.

z

If controller or DVR has no pattern button or function, use shortcut keys with preset numbers. For more

information, refer to “Reserved Preset” in this manual.

Starting OSD Menu

z

Function

Using the OSD menu, Preset, Pattern, Swing, Group and Alarm Input function can be
configured for each application.

z

Enter Menu

[95]

Reserved Preset

z

Description

Some Preset numbers are reserved to special functions.

z

Function

[95]

Enters into OSD menu.

[131~134]

Runs Pattern Function 1 ~ 4

[141~148]

Runs Swing Function 1 ~ 8

[151~158]

Runs Group Function 1 ~ 8

3. OPERATION