Installation, Operation – CNB SSM2065PW User Manual
Page 9
Xpeed Mini Outdoor Speed Dome Camera Series
www.cnbtec.com
17
Sensor Input/Relay Output
z
Sensor Input connection
Before connecting sensors, check driving voltage and output signal type of the sensor. Since output signal
types of the sensors are divided into Open Collector and Voltage Output type in general, the cabling must be
done properly after considering these typed.
Signal
Description
IN COM+
Connect (+) cable of electric power source for Sensors to this port as
shown in the circuit above.
IN1-, IN2-, IN3-, IN4-
Connect output of sensors for each port as shown in the circuit above.
If you want to use Alarm Input, the types of sensor must be selected in OSD menu. The sensor types are Normal
Open and Normal. If sensor type is not selected properly, the alarm can be activated reversely.
Normal Open
Output Voltage is high state when sensor is activated
Normal Close
Output Voltage is high state when sensor is not activated
z
Relay output connection
Maximum allowable electrical load of relay is shown bellow table.
Driving Power
DC
110VAC
Max. Load
24VDC, 1A
125VAC, 0.5A
2. INSTALLATION
2. INSTALLATION
Xpeed Mini Outdoor Speed Dome Camera Series
www.cnbtec.com
18
▣
Check points before operation
z
Before power is applied, please check the cables carefully.
z
The camera ID of the controller must be identical to that of the target camera. The camera ID can be
checked by reading DIP switch of the camera.
z
If your controller supports multi-protocols, the protocol must be changed to match to that of the camera.
z
If you changed camera protocol by changing DIP switch, the change will be effective after you reboot the
camera.
z
Since the operation method can be different for each controller available, refer to the manual for your
controller if camera can not be controlled properly. The operation of this manual is based on the standard
Pelco
®
Controller.
▣
Preset and Pattern Function Pre-Check
z
Check how to operate preset and pattern function with controller or DVR in advance to operate camera
function fully when using controller or DVR.
z
Refer to the following table when using standard Pelco® protocol controller.
Input [Preset Number] and press [Preset] button shortly.
Input [Preset Number] and press [Preset] button for more than 2 seconds.
Input [Pattern Number] and press [Pattern] button shortly.
Input [Pattern Number] and press [Pattern] button for more than 2 seconds.
z
If controller or DVR has no pattern button or function, use shortcut keys with preset numbers. For more
information, refer to “Reserved Preset” in this manual.
▣
Starting OSD Menu
z
Function
Using the OSD menu, Preset, Pattern, Swing, Group and Alarm Input function can be
configured for each application.
z
Enter Menu
▣
Reserved Preset
z
Description
Some Preset numbers are reserved to special functions.
z
Function
Enters into OSD menu.
Runs Pattern Function 1 ~ 4
Runs Swing Function 1 ~ 8
Runs Group Function 1 ~ 8
3. OPERATION
3. OPERATION