Xpeed Mini Outdoor Speed Dome Camera Series

www.cnbtec.com

29

Motion Setup

4. MENU

Setup the general functions of Pan/Tilt motions.

z

MOTION LOCK

[ON/OFF]

If Motion Lock is set to ON, it is impossible to
set up and delete Preset, Swing, Pattern and
Group. It is possible only to run those functions.
To set up and delete those functions, enter into
OSD menu.

z

PWR UP ACTION

[ON/OFF]

Refer to “Other Functions" section.

z

AUTO FLIP

[ON/OFF]

Refer to “Other Functions" section.

z

JOG MAX SPEED

[1°/sec ~360°/sec]

Sets maximum jog speed. Jog speed is
inversely proportional to zoom magnification.
As zoom magnification goes up, pan/tilt speed
goes down.

z

JOG DIRECTION

[INVERSE/NORMAL]

If you set this to ‘Inverse’, the view in the
screen is moving same direction with jog
tilting. If ‘Normal’ is selected, the view in the
screen is moving reversely.

z

FRZ IN PRESET

[ON/OFF]

At start point of preset movement, camera
starts freezing the image of start point. Camera
keeps displaying the image of start point
during preset movement and does not display
the images which camera gets during preset
movement. As soon as camera stops at preset
end point, camera starts displaying live images
which it gets at preset end point.

This function availability should be different by
models.

Xpeed Mini Outdoor Speed Dome Camera Series

www.cnbtec.com

30

„

Parking Action Setup

„

Alarm Input Setup

4. MENU

If Park Enable is set to ON, camera runs assigned function automatically
if there is no PTZ command during assigned "Wait Time".

z

PARK ENABLE

[ON/OFF]

z

WAIT TIME

[1 minute ~ 4 hour]

The time is displayed with "hh:mm:ss" format
and you can change this by 1 min unit.

z

PARK ACTION

[HOME/PRESET/PATTERN/SWING/GROUP]

{

HOME

Camera moves to home position if there is no
PTZ command during assigned "Wait Time".

Match the Alarm sensor input to one of Preset positions. If an external
sensor is activated, camera will move to corresponding preset position
when this item is predefined.

z

ALARMx TYPE

[Normal OPEN/Normal CLOSE]

Sets sensor input type.

z

ALARMx ACT

[NOT USED/PRESET 1~128]

Assign counteraction Preset position to each
Alarm input.