2 disclaimer, 3 safety precautions, 4 service and repairs – Hach-Lange ORBISPHERE 6110 User Manual User Manual
Page 8: 5 class 1 laser

6
General Information
1.3.2 Disclaimer
1.3.3 Safety precautions
1.3.4 Service and repairs
None of the instrument’s components can be serviced by the user. Only personnel from Hach 
Lange or its approved representative(s) is (are) authorized to attempt repairs to the system and 
only components formally approved by the manufacturer should be used. Any attempt at 
repairing the instrument in contravention of these principles could cause damage to the 
instrument and corporal injury to the person carrying out the repair. It renders the warranty null 
and void and could compromise the correct working of the instrument and the electrical integrity 
or the CE compliance of the instrument.
If you have any problems with installation, starting, or using the instrument please contact the 
company that sold it to you. If this is not possible, or if the results of this approach are not 
satisfactory, please contact the manufacturer’s Customer Service.
1.3.5 Class 1 LASER
A Class 1 LASER is installed in this instrument. Class 1 LASERS are products where the 
radiant power of the LASER beam accessible (the accessible emission) is always below the 
Maximum Permissible Exposure value. Therefore, for Class 1 LASERS the output power is 
below the level at which it is believed eye damage will occur. Exposure to the beam of a Class 1 
LASER will not result in eye injury. Class 1 LASERS may therefore be considered safe. 
However, Class 1 LASER products may contain LASER systems of a higher Class but there are 
adequate engineering control measures to ensure that access to the beam is not reasonably 
likely. 
This Class 1 Laser product complies with 21 CFR Chapter 1, sub-chapter J. It is evaluated and 
tested in accordance with EN 61010-1, Safety Requirements for Electrical Equipment for 
Measurement and Control and Laboratory Use and IEC/EN 60825-1, Safety of Laser Products.
CAUTION
The manufacturer is not responsible for damages resulting from misapplication or misuse of 
this product and rejects the regulation of such damages, including direct, indirect and 
consequential damages, and in full accordance with applicable law. The user is solely 
responsible for the identification of critical applications and risks and taking appropriate 
measures to protect processes during a possible equipment malfunction.
DANGER
Risk of finger trapping.
A silicon insert is located on the transparent front door to assist in lifting and 
lowering the door when adding or removing packages for analysis. Under no 
circumstances must this silicon insert be removed.
WARNING
Electrical danger and fire hazard. Only use the supplied power cable. Only qualified experts 
may perform the tasks detailed in the installation section of this manual, while adhering to all 
locally valid safety regulations.
WARNING
Removable power cables must not be replaced with inadequately dimensioned power cables.