Operation—Profibus PA

67

7.2 Profibus PA communication

Profibus uses a master/slave data exchange technique. The master
(typically a PLC) generates queries to individual slaves. The slaves, in
turn, reply back with a response to the master. A Profibus message
contains the information required to send a query or request, including
the slave address, function code, data, and a checksum. See

Table 13

on page 68

for Profibus communication parameters in case of errors.

Select Sensocheck

CHECK ON

Continuous Sensocheck evaluation of
sensor function

CHECK OFF (default)

Enter Profibus address

2

Edit

0001–0126 BUS (default: 0126)

1

Temperature compensation is not available for salinity.

2

Use only when there is no bus connection. The transmitter will restart and set all

parameters to default values. Individual settings must be entered once more.

7.1.2