beautypg.com

Vi. shutdown, Vii. maintenance, Warning – Cashco DA4 User Manual

Page 3

background image

IOM-DA4

3

8. When

fl ow is established steady enough that the

outlet (downstream) block valve is fully open, begin
to slowly close the bypass valve if installed.

9. Develop

system

fl ow to a level near its expected

normal rate, and reset the regulator set point by
adjusting the loading system pressure control
setpoint to the desired outlet pressure level.

SECTION VI

10. Reduce system fl ow to a minimum level and

observe pressure set point. Outlet pressure
will rise from the set point of Step 9 for a Model
DA4. The max i mum rise in outlet pres sure on
de creas ing fl ow should not exceed the 10%. If
it does, consult factory.

VI. SHUTDOWN

1. Shutoff auxiliary loading pressure source, if sup-

plied.

2. Shutoff inlet block valve.

3. Allow

suffi cient time for the line pressure down-

stream of the inlet block valve to bleed down.

4. Shutoff the outlet block valve.

5. Relieve the trapped upstream and downstream

pressure and loading pres sure.

6. The regulator may now be removed from the

pipe line or disassembled for inspection and pre-
ven ta tive main te nance while in-line.

VII. MAINTENANCE

A. General:

Item Dynamic

No.

Seal Type

Part Description

13

..................... All

..........................Guide

Bearing/Piston

14 ..................... All ................................. Static Stem Seal

14.1 ............... All ...................... Upper Static Stem Seal

14.2 ............... All ......................Middle Static Stem Seal

14.3 ............... All ...................... Lower Static Stem Seal

15 ..................... All ................................ Cage O-ring Seal

16

.................CW,PW

.............................................. Wiper

17.1

..............CW,PW

................................. Wiper

Washer

17.2 ........... OR,CP,PR ........ Camber Adjusting Washer *

17.3..................

UC.......................................Seal Retainer

19

..................... All

................................................... Cage

20

..................... All

...........................................Valve

Plug

21

..................... All

............................................ Seat

Ring

27 ..................... All ............................. Dynamic Side Seal

27.1 ........... CP,CW ................................. TFE Cap Seal

27.2

...........CP,

CW

..................... O-ring Energizer/Seal

27.3 .............. UC .......... U-Cup Seal w/Metal Energizer

27.4

.............. OR

....................................... O-Ring

Seal

27.5 ........... PR,PW ............................. Piston Ring Seal

27.6 ........... PR,PW ............. Piston Ring SST Energizer

* Metal Diaphragm Only.

SECTION VII

A detailed view of the dynamic side seal parts
is shown in Figure 1 on the next page.

6. Sub-Sections B. through F. are for con struc-

tions that do NOT include any Opt-81 High
Outlet Pressures with di a phragm support.
These con struc tions are cov ered in Sub-
Sec tion G.

5. The Inner Trim is re moved and replaced in

the body ( 23) as an assemblage of parts.
The Inner Trim Assembly, here in af ter called
ITA, consists of the following parts:

1. The regulator may be serviced without

re mov ing the regulator from pipeline. The
reg u la tor is designed with quick-change trim
to simplify maintenance.

2. Record the nameplate information to req-

ui si tion repair parts for the regulator. The
in for ma tion should include: size, KM Product
Code, Serial Number, and internal or ex ter nal
sens ing. (NOTE: Never both types of sens-
ing.)
If external sensing is used, be sure that
the external sensing line is connected.

3. Refer to Section X for recommended repair

parts. Only use original equipment parts
sup plied by Cashco/KM for re build ing or
re pair ing reg u la tors.

4. Owner should refer to owner's procedures

for removal, handling, cleaning and disposal
of nonreuseable parts, i.e. gaskets, etc.

NOTE: On regulators originally supplied
as “oxygen clean” – Opt-55, maintenance
must include a level of cleanliness equal to
Cashco cleaning standard #S-1134.

WARNING

SYSTEM UNDER PRESSURE. Prior to per form ing any
maintenance, isolate the reg u la tor from the system and
relieve all pressure. Failure to do so could result in per-
sonal injury.

This manual is related to the following products: