beautypg.com

Cashco 9540R P/P User Manual

Page 7

background image

IOM-9540R

7

PART

COLOR

NO

NO.

CODE

COILS

light

gray

830-69-5-08002-00

7 -1/4

olive

green

830-69-5-08001-00

6 -3/4

light

yellow

830-69-5-08000-00

5 -3/4

Figure 8

Figure 9

CHARACTERIZATION CAM SELECTION & ORIENTATION

VS. CONTROL VALVE ACTION –

RANGER & PREMIER PRODUCTS

Figure 7

Input

Product

Product

"SIG"

& Cam

Color

& Cam

Color

psig

Character

P/N*

Code

Character

P/N*

Code

Light

Olive

3-15

-08000-

Yellow

-08001-

Green

Light

Olive

3-9

-08000-

Yellow

Ranger -

-08001-

Green

Ranger -

Light

Linear

Olive

9-15

=%

-08000-

Yellow

or

-08001-

Green

Olive

Premier

Light

3-7

-08001-

Green

=%

-08002-

Gray

Olive

Light

7-11

-08001-

Green

-08002-

Gray

Olive

Light

11-15

-08001-

Green

-08002-

Gray

TABLE 3

RANGE SPRING SELECTION

* Complete Cashco part number (P/N) is as shown in Figure 7. Table 3 indicates the

missing numbers of the complete P/N; general P/N = 830-69-5-_ _ _ _ _-00.

X

Signal = min
Output Load = min
Valve Position = closed

Inner wall of
baseplate (26)

Signal = max

Output Load = max

Valve Position = open

Characteristic: = %
Actuator Action: ATO-FC
Positioner Action: Direct

RANGER QCT

X

1/2"

12.7 mm

31

31

24

Characteristic: = %
Actuator Action: ATO-FC
Positioner Action: Reverse

RANGER QCT

Signal = min
Output Load = max
Valve Position = open

Signal = max

Output Load = min

Valve Position = closed

Inner wall of
baseplate (26)

X

31

31

24

Control Valve

Positioner

Plug Action

Eckardt

Action/Fail

Changeover

Stem Travel

With Signal

Fail Action

Position

Action

Plate Setting

Direction

Increasing

Position

ATO-FC

Direct

CW to Close

Opens

Closed

CCW to Open

ATC-FO

Direct

CW to Close

Closes

Open

CCW to Open

ATC-FO

Reverse

CW to Close

Opens

Closed

CCW to Open

ATO-FC

Reverse

CW to Close

Closes

Open

CCW to Open

w/o Signal

N

U

N

U

N

U

N

U

TABLE 2