background image

12

Available versions of the
electronic module

The electrical connection of all the devices is made through
a male fixed connector.

s

upply

voltage

o

utput

flow

sensor

o

rder

code

12-36 V DC

filtered and

regulated

2 transistors,
NPN and
PNP

Hall, short

419587

Hall, long

419589

energized via the

Bürkert transmitter

the flow sensor is

connected to

1 NPN
transistor

Hall Low
Power,
short

419591

Hall Low
Power, long

419593

without

1 sinus
output

Coil, short

419583

Coil, long

419585

English

13

6. TechnicAl DATA
operating conditions

Ambient temperature -15 °C to +60 °C
Air humidity

< 80%, non condensated

Protection rating

IP65 acc. to EN 60529, female
connector wired, plugged and
tightened

conformity to standards and
directives

The device conforms to the EC directives through the fol-
lowing standards:
• EMC: EN 61000-6-2, EN 61000-6-3
• Vibration: EN 60068-2-6
• Shock: EN 60068-2-27
• Pressure: Article 3§3 of the Pressure Directive 97/23/CE.

English

13

14

Acc. to pressure directive 97/23/CE, the device can only
be used in the following cases (depending on the max.
pressure, the DN of the pipe and the fluid):

type of fluid

conditions

Fluid group 1 § 1.3.a

Only DN ≤ 25

Fluid group 2 § 1.3.a

DN ≤ 32
or DN > 32 and PNxDN ≤ 1000

Fluid group 1 § 1.3.b

DN ≤ 25
or DN > 25 and PNxDN ≤ 2000

Fluid group 2 § 1.3.b

DN ≤ 400

General data

Tab. 1:

Temperature-pressure dependency curves

10

9
8
7
6
5
4
3
2
1
0

-10

+10

+30

+50

+70

PVDF

PVDF (PN10)

PVC (PN10)

PP (PN10)

PVC + PP

11

A

P (bar)

T (°C)

Metal

English

15

Pipe diameter

DN20 (except for DN20 specified
p.27) to DN400. The appropriate
diameter is determined using the flow
rate / DN / fluid velocity graphs.

Pressure class

Depends on the material of the fitting
used and on the fluid temperature.
See Tab. 1

Fluid temperature

• with fitting S020 in

metal or PVDF

• with fitting S020

in PP

• with fitting S020 in

PVC

The fluid temperature may be restricted

by the fluid pressure: Refer to the

temperature-pressure dependency

curves for the device. See Tab. 1
• -15 to +80 °C

• 0 to +80 °C

• 0 to +50 °C

Flow rate measuring

range

Hall and Hall Low Power versions: 0,3

to 10 m/s
Sinus version: 0,5 to 10 m/s

Accuracy, with standard

K factor

≤ ±

(0.5 % of the full scale + 2.5 % of

the measured value)*

Linearity

≤ ±0,5 % of the full scale*

Repeatability

±0,4 % of the measured value*

* Determined in the following reference conditions: medium =
water, water and ambient temperatures 20 °C, min. upstream and

English

15