beautypg.com

Burkert Type 8020 User Manual

Page 3

background image

8

note

the device may be damaged by the fluid in contact
with.
• Systematically check the chemical compatibility of the

component materials of the device and the fluids likely

to come into contact with it (for example: alcohols,

strong or concentrated acids, aldehydes, alkaline

compounds, esters, aliphatic compounds, ketones,

halogenated aromatics or hydrocarbons, oxidants and

chlorinated agents).

note

elements / components sensitive to electrostatic
discharges
• This device contains electronic components sensitive

to electrostatic discharges. They may be damaged

if they are touched by an electrostatically charged

person or object. In the worst case scenario, these

components are instantly destroyed or go out of order

as soon as they are activated.

• To minimise or even avoid all damage due to an elec-

trostatic discharge, take all the precautions described

in the EN 61340-5-1 and 5-2 norms.

• Also ensure that you do not touch any of the live elec-

trical components.

English

9

4. GenerAl informATion

To contact the manufacturer of the device, use following
address:
Bürkert SAS
Rue du Giessen
BP 21
F-67220 TRIEMBACH-AU-VAL
The addresses of our international sales offices are
available on the internet at:

www.burkert.com

Warranty conditions

The condition governing the legal warranty is the conforming
use of the device in observance of the operating conditions
specified in this manual.

information on the internet

You can find the user manuals and technical data sheets
regarding the type 8020 at:

www.burkert.com

English

9

10

5. DescripTion
Area of application

The 8020 flowmeter is intended to measure the flow rate of
neutral or slightly aggressive liquids free of solid particles.

construction

The device is made up of an electronic module and of a flow
sensor. The device can be installed in any pipe from DN20
(except for DN20 specified p. 27) to DN400.
The device has, depending on the version, 1 NPN tran-
sistor output, 2 transitor outputs, NPN and PNP, or 1 sinus
output (coil output).
Electrical connection is made via a male fixed connector.

measuring principle

The circulation of fluid within the pipe causes the paddle
wheel of the sensor to rotate. The flowmeter detects the
rotation of the paddle-wheel and generates a signal which
frequency f is proportional to the flow rate Q, using the
formula f = KxQ.
f = frequency in Hertz (Hz)
K = K factor of the S020 fitting used, in pulse/litre
Q = flow rate in litre/second

English

11

Description of the name plate

FLOW:8020-FKM-PVDF
HALL LONG 12-36VDC
OUT:OPENCOL.NPN/PNP

S-N:21219
419589 W48LG

Made in France

1

2

3

4
5

6

7

8

9

1.

Quantity measured and type of the device

2.

Material of the seal

3.

Material of the flow sensor frame

4.

Version of the flow sensor and, when required, power
supply

5.

Output data

6.

Conformity logo

7.

Manufacturing code

8.

Serial number

9.

Order code

English

11