7

GeneralSafetyInstructions

3.

general safety instructiOns

These safety instructions do not make allowance for any:

• Contingencies and events which may arise during the installation, operation and maintenance of the devices.

• Local safety regulations; the operator is responsible for observing these regulations, also with reference to the

installation personnel.

DangEr!

risk of electric shock!

There is a serious risk of injury when reaching into the device.

• Before reaching into the device, always switch off the power supply and safeguard to prevent re-activation!

• Connect several electromotive rotary actuators always with phase separation via a switch.

• Protect the device with a mains-operated fuse.

• Observe applicable accident prevention and safety regulations for electrical equipment!

Danger of explosion!

For specific device designs there is a risk of explosion if the device is opened in the explosion-protected area.

• Follow the safety instructions on the type label!

Danger of explosion caused by electrostatic charge!

If there is a sudden discharge from electrostatically charged devices or persons, there is a danger of explosion in
the EX area.

• Take appropriate measures to prevent electrostatic charges in the EX area.

• Clean the device surface by wiping it gently with a damp cloth.

general hazardous situations.

To prevent injury, ensure:

• That the system cannot be activated unintentionally.

• Type 3005 must not be used in areas where there is a risk of explosion (in this case please use type 3004).

• Do not put any loads on the body (e.g. by placing objects on it or standing on it).

• Do not make any external modifications to the device bodys. Do not paint the body parts or screws.

• Do not install the actuator with the cover facing down (head first).

• Installation and repair work may be carried out by authorized technicians only and with the appropriate tools.

• After an interruption in the power supply or pneumatic supply, ensure that the process is restarted in a

defined or controlled manner.

• The device may be operated only when in perfect condition and in consideration of the operating instructions.

• The general rules of technology apply to application planning and operation of the device

.