beautypg.com

Maintenance, troubleshooting, Safety instructions 10.2. maintenance work – Burkert Type 2051 User Manual

Page 15

background image

15

Maintenance, Troubleshooting

10.

mainTenance,
TrOuBleshOOTing

safety instructions

10.1.

Danger!

danger - high pressure in the equipment!

Before loosening the lines and valves, turn off the pressure and

vent the lines.

Warning!

risk of injury from improper maintenance!

Maintenance may be carried out by authorised technicians only

and with the appropriate tools!

risk of injury from unintentional activation of the system and
uncontrolled restart!

Secure system from unintentional activation.

Following maintenance, ensure a controlled restart.

maintenance work

10.2.

It is recommended to perform maintenance after every 500 000 to
1 000 000 circuit connections to guarantee a long service life of
swivel actuators. If necessary, the respective sealing elements must
be replaced (see the following chapter

10.3.Replacing of the sealing

elements).

For long-term operation or rough ambient conditions, we recommend
relubrication of the moving parts (e.g. pistons, gear racks) in the actuator
with silicone-free grease (e.g. Barrierta LF 55/3).

A prerequisite for a long service life is the operation of the swivel
actuator with filtered compressed air.

english