9

07 ATEX 2048

English

General technical data

6.2. Conformity

In accordance with the EC Declaration of conformity, Type 6144 is
compliant with the EC Directives.

6.3. Standards

The applied standards, which verify conformity with the EC Direc-
tives, can be found on the EC-Type Examination Certificate and / or
the EC Declaration of Conformity.

6.4. Identification of the type variants

Example:

6144

PF01*

JF80*

Type
designation

Type approval code

Electrical connection

* all variants of the flipper valve are listed in the following tables "Type

approval code" and "Electrical connections".

Type approval code:

PF01

Ex ia IIC T6

Installation as a single device

PF02

Ex ia IIC T6

Installation in a block assembly

PF03

Ex ia IIC T5

Installation as a single device

PF04

Ex ia IIC T5

Installation in a block assembly

PF06

Ex ia IIC T4

Installation as a single device

PF07

Ex ia IIC T4

Installation in a block assembly

Electrical connections:

JC09

2 impressed single wires 0.2mm

2

(AWG24)

JC14

3 impressed single wires 0.2mm

2

(AWG24)

JC36

2 impressed FEP wires 0.2mm

2

(AWG24)

JF79

Round connector M8

JF80

Rectangular connector 2-pin

JF81

Rectangular connector 3-pin

JF82

Rectangular connector 2-pin without protective collar

JG78

Rectangular connector 3-pin without protective collar

6.5. Functional data

The solenoid valve 6144 is available in a single and double valve
design with 3 versions each.

Version

Resistance
R20 [

]

Minimum
terminal
voltage [V]

Minimum
current
[mA]

01

Version for the use with
300

supply module

320

9,3

29

02

High-impedance
version

510

11,7

23

03

Version for theuse at
the valve terminal 8650

125

Single valve

6.1

49

Double valve

5.28

42