8

07 ATEX 2048

English

General technical data

6. GENERAL TECHNICAL DATA

DANGER!

Danger of explosion!
Non-compliance or non-observance of the safety-relevant data
and values specified on the rating plate could cause dangerous
situations!
• When using the device, the protection class and the tempera-

ture class must be observed.

Exceeding the voltage stated on the rating plate can cause over-
heating of the device!
• Do not connect the device with a voltage that is higher than

stated on the rating plate.

6.1. Rating plate

Example: (design with rectangular connector)

Double valve type 6144

Single valve type 6144

PTB

07

ATEX 2048

Ex ia IIC T6 Gb

II 2G Ex ia IIC T6 Gb

IEC Ex PTB 07.0063

S/N XXXXXX

D-74653 Ingelfinge

n

CE0102

XXXXXXXX

W24LA

6144, Tambcoil and

P.U.I s. Op. Manual

Fig. 1:

Example of a rating plate for a single and a double valve type 6144

The inscription on the rating plate

Operating principle

Pressure range

Voltage (±10 %)and

current type

Order no.

Type

Output

II 2G Ex ia IIC T4 Gb

PTB approval no.

IEC Ex approval no.

Device group

Device category

Device protection level

Example:

Ignition

protection type

Gas group

Temperature class

Coil serial number

Ident. no.

Manufacturing datefactory/
month/year

Inspection body

Type

PTB

07

ATEX 2048

Ex ia IIC T6 Gb

II 2G Ex ia IIC T6 Gb

IEC Ex PTB 07.0063

S/N XXXXXX

D-74653 Ingelfinge

n

CE0102

XXXXXXXX

W24LA

6144, Tambcoil and

P.U.I s. Op. Manual