Fluid installation – Burkert Type 6144 User Manual
Page 17

17
07 ATEX 2048
English
Assembly / installation
9.2. Fluid installation
WARNUNG!
Risk of injury due to malfunction/escape of medium.
If the exhaust air from other processes is used to generate com-
pressed air for the device, the seals may be destroyed by the
media contained in the air.
• Use only fresh air to generate compressed air for the device.
The installation position of the flipper valve is arbitrary.
Preferably, the drive should be at the top.
Important operating condition for the prevention of
malfunctions:
The valve must have a minimum distance of 5 mm from
other ferromagnetic materials.
Prior to the installation:
WARNING!
Risk of injury from high pressure!
• Before loosening the lines and valves, turn off the pressure and
vent the lines!
→
Clean any possible dirt off the pipelines and flange connections.
→
Install a filter (5 µm) in front of the valve to protect it from
malfunctions.
Installation of type 6144 with Bürkert flange:
(see „Fig. 2: Installation drawing for Bürkert flange“)
WARNING!
Risk of injury through spillage of medium!
Medium that is spilled by leaking connections can result in injuries
(e.g. burns or acid burns).
• Make sure that the sealing gasket included with delivery sits
properly.
→
Insert the sealing gasket into the valve.
→
Correctly allocate the fluid connection configuration 1, 2 and 3
to the valve and the connection plate.
→
Drill holes according to the drill hole-pattern.
→
Screw valve onto the connection plate
→
Check valve for leakage.
Installation of type 6144 with angle flange:
(see „Fig. 3: Installation drawing for angle flange (FS09)“)
→
Correctly allocate the fluid connection configuration 1, 2 and 3
to the valve and the connection plate.
→
Drill holes according to the drill hole-pattern.
→
Screw valve onto the connection plate
→
Check valve for leakage.