Technical data
Typ 2300
B
P
A
Normally open by spring action
I
P
A
Actuating function via reciprocal pressurization
6.2.2. Flow direction below the seat
Depending on the version, the valve is closed against the medium
flow with spring force (control function A, CFA) or with pilot
pressure (control function B or I, CFB or CFI).
As the medium pressure is under the control cone, this pressure
contributes to the opening of the valve.
WARNING!
Medium may be discharged if minimum pilot pressure is too
low or medium pressure too high!
If the minimum pilot pressure is too low for CFB and CFI or the
permitted medium pressure is exceeded, leaks may occur.
• Observe minimum pilot pressure.
• Do not exceed medium pressure (see chapter “Pressure ranges”).
CFA
CFB / CFI
Fig. 1:
Flow direction below the seat
(Rest open/closed, closing against medium)
7. TECHNICAL DATA
7.1. Conformity
Type 2300 conforms with the EC Directives according to the EC
Declaration of Conformity.
7.2. Standards
The applied standards, which verify conformity with the EC Directives,
can be found on the EC Type Examination Certificate and / or the EC
Declaration of Conformity.
7.3. Type label
00203496
2300 A 25M PTFE VA
Tmed -10°C - +185°C
Flow 1 2
Pilot 5,5-7bar
Pmed 16,0bar
W3ZLT
CE
G1" Kvs16,0
CE identification
Permitted pilot pressure
Permitted medium
pressure
Type
Control function (CF)
Orifice of the seat /
actuator size
Sealing material
Body material
Identification
number
Flow direction
Permitted medium
temperature
Date of
manufacture
Main dimensions of
line connection
Flow capacity in standard
production conditions
english