5.

technical data

5.1. Operating conditions

The following values are indicated on the type label:
• Voltage (Tolerance ± 10 %) / Current type
• Coil power consumption (active power in W - at operating temp.)
• Pressure range
• Body material

PVC (PV) or PVDF (PD)

• Seal material

FKM, EPDM

Protection class:

IP65 with accordance with DIN EN 60529 /
IEC 60529 with cable plug, e. g. Bürkert Type
2508

Operating principle:

A (NC)

2/2-way valve, normally
closed

B (NO)

2/2-way valve, normally
opened

5.2. application conditions
Ambient temperature:

PVC 0 - +40 °C
PVDF 0 - +55 °C

Permitted medium temperature depending on body material:

Body material

Medium temperature

PVC

0 °C ... +50 °C

PVDF

0 °C ... +70 °C

Pressure - Temperature Diaphragm for PVC and PVDF:

10 20 30 40 50 60 70 80

1

2

3

4

5

6

7

PVC

PVDF

Temperature [°C]

Pressure

[bar]

english

Permitted media depending on seal material:

Seal material

Permitted media

FKM

Oxidizing acids and substances, water

EPDM

Alkalis, alkaline washing and bleaching lyes,
water, oil- and grease-free media

Operating duration
Unless otherwise indicated on the type label, the solenoid system is
suitable for continuous operation.

Important information for functional reliability during continuous
operation!
If standstill for a long period at least 1-2 activations per day
are recommended.

Service life
High switching frequency and high pressures reduce the service life.

5.3. conformity
In accordance with the EC Declaration of conformity, the solenoid valve
Type 0142 is compliant with the EC Directives.

5.4. standards
The applied standards, which verify conformity with the EC Directives,
can be found on the EC Type Examination Certificate and / or the EC
Declaration of Conformity.

5.5. type label

Type

Operating

principle

Orifice

Seal material

Body material

Id. Number

Manufacture-Code

Voltage, Frequency, Power

consumption

Connection thread, Nominal

pressure

0142 A 20,0 FKM PV

Made in Germany

00042005

W17MG

230V 50-60Hz 5W

025 P

N 0,5

-

6 bar

english

6.

installatiOn

6.1. safety instructions

Danger!

Risk of injury from high pressure in the equipment!
• Before loosening the lines and valves, turn off the pressure and

vent the lines.

Risk of injury due to electrical shock!
• Before reaching into the system, switch off the power supply and

secure to prevent reactivation!

• Observe applicable accident prevention and safety regulations for

electrical equipment!

Warning!

Risk of injury from improper installation!
• Installation may be carried out by authorized technicians only and

with the appropriate tools!

Risk of injury from unintentional activation of the system and
an uncontrolled restart!
• Secure system from unintentional activation.
• Following installation, ensure a controlled restart.

6.2. before installation
Installation position: any, actuator preferably upwards.
Procedure:

Check pipelines for dirt and clean.

Install a dirt filter before the valve inlet (

≤ 500 µm).

6.3. installation

Insert O-ring

Insert

Tighten union nut - evenly by

hand only

english