4-4

Model SLA7840

Section 4 Maintenance
& Troubleshooting

Installation and Operation Manual

X-PR-SLA7800-RT-eng

Part Number: 541B048AAG

August, 2009

Remove the sensor connector from the PC Board for this procedure.

OHMMETER CONNECTION

RESULT IF ELECTRICALLY FUNCTIONAL

Open circuit on ohmmeter. If either heater (1) or

Pin 1 or 4 to meter body

sensor common (4) are shorted, an ohmmeter
reading will be obtained.

Pin 4 to Pin 2

Nominal 1100 ohms reading, depending on

Pin 4 to Pin 3

Pin 5 to Pin 1

Nominal 1000 ohm reading.

Pin 6 to Pin 7

Nominal 580 ohm reading.

Table 4-1 Sensor Troubleshooting

temperature and ohmmeter current.

SENSOR

SCHEMATIC

PIN

NO.

FUNCTION

1

Heater

Upstream

2

Temperature

Sensor (Su)

Downstream

3

Temperature

Sensor (Sd)

4

Sensor Common

5

Heater Common

6

Thermistor

7

Thermistor