Confirms loading of the factory settings
Goes back to the reserved setup screen
8.4
MACHINE CALIBRATION
Reserved for Technical Service
Saves the calibration values
Confirm
Goes back to the setup screen
Goes back to the main screen
Reserved Setup
1. Select a commercial wheel or sample wheel based on the type of wheel you intend to use for calibration and press
the
button.
2. Mount the wheel selected, close the guard and press the
button.
3. Set the value of the sample weight used for the calibration.
4. Open the guard, apply the sample weight on the outside of the wheel, close the guard and press the
button.
5. Open the guard, apply the sample weight on the inside of the wheel in the same position as it was applied on the
outside, close the guard and press the
button.
6. Move the sample weight to 12 o’clock and press the
button.
7. Press the calibration save button
.
8. Press the
button to go back to the measurement screen.