CEMB USA C202 User Manual
Page 21
I 0592 - 21
GB
6 - SETUP
(see Diagram showing access to the menus)
The Setup screen provides the user with many possibilities required for presetting the machine according to his own
requirements. Such settings remain unaltered even when the machine is switched off.
The following buttons are enabled:
: return to previous window
: return to Measurement screen
from
to
: for selection of the parameter.
6.1 - Language
This function allows selecting the language to be used for displaying descriptive and diagnostic messages regarding
machine operation.
6.2 - Unit of unbalance measurement
It is possible to select whether to display the unbalance values expressed in grams or ounces.
6.3 - Unbalance display threshold for truck/car
This consists of the unbalance threshold below which the wording “OK” appears on the screen at the end of the spin
instead of the unbalance; the presettable values vary according to the unit of measurement selected.
6.4 - Unbalance display pitch for truck/car
This represents the display pitch of the unbalance and varies according to the unit of measurement selected. The
selection “5 g” (1/4 oz) for cars and of “50 grams” (1.0 oz.) for trucks.enables display of the correction values on
both sides such as to bring the static unbalance to 0 (theoretical). It is recommended to preset this function as
standard use of the machine as it improves the balancing quality. The computer makes a complex calculation which
allows cancelling the residual static unbalance by varying the value and position of the counterweights of fi xed value.
6.5 - Spin with guard closed
When “ON” is selected the automatic start of the spin is enabled upon closing the guard.
6.6 - Screen-saver time
When the machine remains unused for longer than the time preset with this function, the processor automatically
returns to the screen-saver screen. Preset the time in minutes.
6.7 - Visual eccentricity check
At the end of the spin, when the measured unbalance values reappear on the screen, it is possible to open the guard
for a visual check to see if the wheel is eccentric or not while the wheel is gradually dropping in speed. On the other
hand, if the guard is left closed, the machine completes the normal positioning.
6.8 - Acoustic signal
When “ON” is selected, an acoustic signal (beep) is given in the following cases:
- when any button is pressed;
- upon reaching the correct angular weight application position, in the Measurements screen;
►
►
►
►
►
►
►
►