I 0592 - 17

GB

5.5.2 - “SPLIT” control

The SPLIT function is only possible in the case of static unbalance or ALU on the outside. It serves for concealing
any stick-on unbalance correction weights behind the rim spokes.

PRESETTING THE NUMBER OF RIM SPOKES

From the STATIC or ALU measurement screen, press

;

A window appears on the display indicating the currently preset number of spokes

Set the required number of spokes in the range 3 to 12 by pressing

and

Press

to confi rm the presetting

Bring a spoke to the 12 o’clock position

Press

; the measurement screen reappears with the unbalance values already split

The ALU unbalance on the inside does not vary while as regards the STATIC unbalance and that ALUS on the
outside, two weights appear for the same side:

Gradually turn the wheel until an unbalance value appears;
Apply an adhesive weight of the value indicated on the screen for the outer or STATIC side, behind the

spoke in the 12 o’clock position;
Again turn the wheel until a new unbalance value appears;
Apply an adhesive weight of the value indicated on the screen for the outer or STATIC side, behind the

spoke in the 12 o’clock position;
Perform a run to check for correct wheel balancing.

Note: when SPLIT is enabled, the icon

is shown on the left of the screen.