TG0045A

Section 5: Advanced Troubleshooting

(CONT’D)

If you have questions about your alternator or any of these test procedures, or if you need to locate a Factory Authorized Service Distributor, please contact us at:

C. E. Niehoff & Co.• 2021 Lee Street • Evanston, IL 60202 USA

TEL: 800.643.4633 USA and Canada • TEL: 847.866.6030 outside USA and Canada • FAX: 847.492.1242

After power up, measure voltage on alternator 14 V output terminal. Is this voltage greater than 5 V?

Yes

No

Chart 5 – Auto Select of Operating Mode (N3232 Only)

Alternator will operate in dual voltage mode
with 200 A output limit on 28 V and 140 A out-
put limit on 14 V to a combined total of 200A.

T

T

Both diagnostic LEDs will flash per Table 1.

Alternator will operate in single voltage mode
with 200 A output limit on 28 V. No 14 V out-
put.

T

T

Only 28 V diagnostic LED will flash per Table 1.