TG72A

Figure 4—Alternator Schematic Diagram

Section B: On-Vehicle Troubleshooting

BR

R

G

R

BR

A2-216 Regulator Troubleshooting

A2-216 regulator is either attached directly to the

outside of alternator.
Main diagnostic feature is a green lens LED located on

the front of the regulator. LED indicates whether regula-

tor has been energized. See Table 2 for LED indication

and status.
Regulators with OVCO (overvoltage cutout) will trip at

vehicle electrical system voltages

above 32 volts that

exist longer than 3 seconds. OVCO feature detects high

voltage and reacts by signaling the alternator field

circuit to open. This turns off alternator. Restarting

engine resets OVCO circuit. Regulator regains control

of alternator output voltage.

TABLE 2 — A2-216 Regulator

LED Indications and Status

INDICATION

STATUS

ON steady

Normal regulator operation.
Alternator is producing output.

FLASHING

Regulator is receiving energize
signal. LED will fl ash until
alternator produces output.

OFF

Regulator is not receiving energize
signal or OVCO has tripped.