beautypg.com

C180-2 alternator, W/ a8-207 rectifi er-regulator – C.E. Niehoff & Co. C180etc and C181etc Installation User Manual

Page 3

background image

II162A

Page 3 of 4

Figure 6 - C180-2/A2-207 Component Interconnection Diagram

C180-2 Alternator

w/ A8-207 Rectifi er-Regulator

1. Install rectifier-regulator assembly in location

determined by customer, using hardware and
torque specified by customer.

2. Remove shipping spacers from both sides of

rectifier-regulator.

3. Connect rectifier-regulator to alternator

with wiring conduit shown in
Figure 5 and 6.

4. Output conduit supplied by customer

connects rectifier-regulator with
customer circuit and consists of
B+ and B– output leads plus
R and D+ terminal leads if used.

5. R circuit current: 3 A max

Square wave signal: 0-30 V
Alternator speed formula: RPM=f(Hz)•10

6. Alternator is configured for self-

energization.

7. D+ terminal is the charge warning

lamp (CWL) connection.

8. Series connected isolation diode in the

B+ circuit is not permissible.

9. When wiring inside rectifier-regulator cover is

complete, re-install cover and torque hardware
to 5.4 Nm/48 lb. in.

Figure 5 - A8-207 Rectifier-Regulator Cover Connections

To alternator

See step 2. M25 x 1.25 pipe thread for
connecting output conduit assembly