ULTRA EDGE SERVO ROLL FEED 2/14/
2003
7
3 PROGRAMMING THE ULTRA EDGE SERVO ROLL FEED SYSTEM -
OVERVIEW
NOTE: Before attempting any programming, make sure that the “PROGRAMMING LOCKED /
UNLOCKED” key switch is in the “Unlocked” position.
NOTE: After power shutdown, WAIT for 5 seconds before powering up the Feed.
Turn on the main power disconnect switch. This applies power to the control power supply. Press the green Power
On push-button. The button will illuminate and the OPERATOR terminal display will be visible.
Wait for the IN POSITION light to illuminate.
Press any key to begin.
P / A I n d u s t r i e s
R e a l l y C o o l F e e d
V e r s i o n 1 . 0 0 s t d
H i t a n y k e y t o c o n t .
NOTE: The OPERATOR terminal has three mode keys, they are:
● “OPER”
● “TOOLS”
● “SETUP”
NOTE: ▓ The flashing cursor is waiting for the value to be entered.
NOTE: < The pointer prompts to press the “ENTER” key.
NOTE: To confirm any value, press “ENTER”.