ULTRA EDGE SERVO ROLL FEED 2/14/

2003

19

E d i t T o o l <
A c t i v a t e T o o l
C r e a t e N e w
P r e s s T O O L S t o E x i t

Enter desired tool number or select it from the tool list using

and keys and press the “ENTER” key again.

E d i t T o o l #

A r r o w k e y s t o s c r o l l
P r e s s T O O L S t o e x i t

E d i t T o o l # 1

A r r o w k e y s t o s c r o l l
P r e s s T O O L S t o e x i t

Position cursor next to desired parameter, enter the new value, and press the “ENTER” key.

T o o l # 1
L e n g t h 2 0 . 0 0 0
C o u n t C o n t . R u n
P r e s s T O O L S f o r n e x t

Press “TOOLS” key to open next screen. Position cursor next to desired parameter, enter new value, and press the
ENTER” key.

T o o l # 1
S p e e d 7 2
D w e l l 0
T O O L S - n e x t B K S P - P r e v

Press “TOOLS” key to open next screen. Position cursor next to desired parameter, enter new value, and press the
ENTER” key.

T o o l # 1
A c c e l 4 0 0 . 0
D e c e l 4 0 0 . 0
T O O L S - n e x t B K S P - P r e v

NOTE: The following six screens are part of the optional PLS package and displayed only if the corresponding
software is loaded.

Press “TOOLS” to open the next screen. Position cursor next to desired parameter, enter new value, and then press
ENTER” key.