PA Industries Edge Servo Roll Feed SRF-100/125/200/300/400/500/600 - Operation Manual User Manual
Page 26

ULTRA EDGE SERVO ROLL FEED 2/14/
2003
26
4.6 HOW TO EDIT “SETUP” PARAMETERS
NOTE: Make sure that the PROGRAMMING “LOCKED / UNLOCKED” key switch is in “Unlocked”
position. If the current screen is one of the setup screens (they all have message on the last line “ Press
“SETUP” for next”), press the “OPER” key to exit setup screens.
Press “SETUP” key three times, position cursor next to desired parameter, enter in new value, and press the
“ENTER” key.
J o g S p e e d % 5
J o g A c c e l 1 0 . 0
J o g D e c e l 1 0 . 0
P r e s s S E T U P f o r n e x t
Press “OPER” key if editing is done or press “SETUP” key to open next screen.
4.7 HOW TO EDIT LENGTH FROM OPERATOR SCREEN
Locate the OPERATOR screen, position cursor next to the Length, enter new value, and press the “ENTER” key.
L e n g t h 1 . 0 0 0
C o u n t C o n t . R u n
L e n g t h A d j u s t m e n t
P r e s s O P E R t o e x i t
4.8 HOW TO EDIT COUNT FROM OPERATOR SCREEN
Locate the OPERATOR screen, position cursor next to the Count, enter new value, and press the “ENTER” key.
Enter “0” for continuous run.
L e n g t h 1 . 0 0 0
C o u n t C o n t . R u n
L e n g t h A d j u s t m e n t <
P r e s s O P E R t o e x i t
4.9 HOW TO MICRO ADJUST LENGTH USING LENGTH ADJUSTMENT
Locate the OPERATOR screen, position pointer next to the Length Adjustment and press the “ENTER” key.
L e n g t h 1 . 0 0 0
C o u n t C o n t . R u n
L e n g t h A d j u s t m e n t <
P r e s s O P E R t o e x i t
L e n g t h 1 . 0 0 0
U s e A r r o w K e y s t o
A d j u s t L e n g t h
P r e s s O P E R t o e x i t
Adjust Length using “
↑” and “↓” keys and then press “OPER” to exit adjusting.