BRAY Series 52 Valve Status Monitor
Operation and Maintenance Manual
8
Non-Adjustable Target Mounting
The S52 Valve Status Monitor is offered with a non-adjustable
target. The non-adjustable target is a one piece puck style target
with metal inserts offset by 90°. The yellow pointer however is
adjustable and can be positioned however you require; when the
unit is mounted at the factory the pointer will be in line with the
valve disc. All components of the non-adjustable kit are shown below in Figure 3. The procedure for mount-
ing the non-adjustable target is described on the next page. Note: when configuring this target with your
input monitoring device pay close attention to metal insert position versus sensor position as your actuator
rotates from open to close.
Step 7: Place the S52 on the actuator, aligning the holes in
the sensor with the mounting holes of the actuator. Insert the
cover over the indicator and align the mounting holes of the
cover with those of the sensor. Use the longer mounting bolts
supplied with your kit and tighten the cover and sensor to the
actuator.
Figure 3: Non-Adjustable Target with pointer.
Mounting of the non-adjustable target:
Insert the target on the pinion of the pneumatic
actuator. Based on what position your pinion/ac-
tuator is in, one of the metal inserts of the target
will be directly in front of switch ‘1’ or switch
‘2’ on your sensor. When your quarter turn ac-
tuator rotates 90° to its opposite travel limit, the
other metal insert of the target will be directly
in front of switch ‘2’ or switch ‘1’, respectively.
Position your actuator to yield your desired in-
dication results.
Figure 4: Non-adjustable Target mounting