4. Setting the output voltage (0x23)

1

st

byte

Start bit (0xAA )

2

nd

byte

Address(0x00~0xFE)

3

rd

byte

Command(0x23)

4

th

byte

The byte 0 of output voltage value

5

th

byte

The byte 1 of output voltage value

6

th

byte

The higher byte of output voltage value

7

th

byte

The highest byte of output voltage value

8

th

to 25

th

byte

System reserve

26

th

byte

Check sum


5Setting the output current (0x24)

1

st

byte

Start bit (0xAA )

2

nd

byte

Address (0x00~0xFE)

3

rd

byte

Command(0x24)

4

th

byte

To set the low byte of current value (1 represents 1 mA)

5

th

byte

To set the high byte of current value

6

th

to 25

th

byte

System reserve

26

th

byte

Check sum







6. Setting the communication address (0x25)

1

st

byte

Start bit ( 0xAA )

2

nd

byte

The current address of power supply(0x00~0xFE)

3

rd

byte

Command(0x25)

4

th

byte

The new address

5

th

to 25

th

byte

System reserve

26

th

byte

Check sum

7. Reading the measured output current/voltage, maximum voltage setting,

voltage/current setting, and the states of power supply. (0x26)

1

st

byte

Start bit ( 0xAA)

2

nd

byte

Address(0x00~0xFE)

3

rd

byte

Command(0x26)

4

th

byte

Byte 0 of measured output current value

5

th

byte

Byte 1 of measured output current value

6

th

byte

Byte 0 of measured output voltage value

7

th

byte

Byte 1 of measured output voltage

8

th

byte

Byte 2 of measured output voltage

Note:

Suppose you want to set the maximum current to 3.12 A. Since 1

represents 1 mA, 3.12 A translates to 3,120 in decimal. With 2 bytes in Hex, that
would be 0x0C30. Since the bytes are ordered in little-endian format, 0x30 would
be the 4

th

byte, and 0x0C as 5

th

byte.

This manual is related to the following products: