3 if the power supply does not turn on, 4 to adjust the carrying handle – B&K Precision 1785B - Manual User Manual
Page 10
10
1.3 If the Power Supply Does Not Turn On
Use the following steps to help solve problems you might encounter when turning on the instrument. If
you need more help, refer to chapter 6 for instructions on returning the instrument to the supplier for
service.
1. Verify that there is AC power to the power supply.
First, verify that the power cord is firmly plugged into the power receptacle on the rear panel of the power
supply. You should also make sure that the power source you plugged the power supply into is
energized. Then, verify that the power supply is turned on.
2. Verify the power-line voltage setting.
The line voltage is set to the proper value for your country (110VAC or 220VAC). Change the voltage
setting if it’s not correct.
3. Verify that the correct power-line fuse is installed.
If the fuse was damaged, please see the table below to replace the fuse for your power supply.
Model
Fuse Description
1785B,
1786B,
1787B
Fuse 2.5A T 250V for 220VAC
Fuse 5A T 250V for 110VAC
1788
Fuse 3.15A T 250V for 220VAC
Fuse 6.3A T 250V for 110VAC
1.4 To Adjust the Carrying Handle
To adjust the position, grasp the handle by the sides and pull outward. Then, rotate the handle to the
desired position.
Bench-top viewing positions Carrying position