B&K Precision 1785B - Manual User Manual
Page 18
18
supply.
Step1. Press key.
Step2. Select >MAX VOLT by using
▲
and
▼
key.
Step3. Press key.
Step4. Change the voltage value by using numeric keys to or
▲
and
▼
key.
Step5. Press key.
Initiating the Output state(>INIT OUT)
This instruction can initiate the output state when the power supply is powered on. If you select ON,
the power supply will initiate the output to OFF state when the power supply is powered on. If you
select OFF, the output will remain the same state as last time you turned off the power supply
Initiating the Output Voltage (>INIT VOLT)
This instruction can set the initial output voltage. If you select ON, the power supply will initiate the
output voltage to 0Volt when the power supply is powered on. If you select OFF, the output voltage
will remain as the same volts as the last time you turned off the power supply
Setting the Key Sound(>KEY SOUND)
This instruction can switch on/off the buzzing sound when you press any key, If you select ON, the
buzzer will sound when any key was pressed. If you select OFF, the buzzer will not sound when the
keys were pressed.
Setting the Baud Rate(>BAUDRATE)
This instruction can change the communication baud rate for the power supply, the baud rate
range is 4800,9600,19200 or 38400。Before the communication, you must make sure that there
is same baud rate between the power supply and the computer.
Enter
Menu
Note:
After you setting the maximum voltage value, the output voltage setup should
be in the range from 0 volt to maximum voltage.
The default maximum voltage is
the full voltage range of its model.
Note:
Default selection is ON and the output state is always OFF state.
Note:
Default setting is ON and the output voltage is 0 volt.
Note:
Default setting is ON; the buzzer will sound when you press any key.
Enter
9
0