Functions/displays, Individual null function, Computation range display – Atec Yokogawa-WT1800 User Manual
Page 3: User-defined event function, Help function
A high resolution display with a resolution about 2.6-fold higher than Yokogawa’s previous
model
*
is employed. More setting information and measurement data can be displayed.
Measurement data can be displayed on a single screen,
along with the respective detailed setting information of 6
inputs, such as a voltage range, current range,
synchronization source, wiring system, and filter. You do
not need to switch display screens frequently to confirm
the settings.
With the WT1800, the data update rate can be selected
from 9 options from the fastest data update rate of 50 ms
to an update rate of 20 s for low-speed measurements.
For example, if you want to save the average data at a
1-minute interval and inappropriately set the update rate
of 50 ms, measurement results may be not correct
because data can be saved only at a 1-minute interval
(once every 20 times).
Such a risk can be avoided by setting the update rate that
is suited to the interval at which you want to save data.
The setting ranges of voltage and current are
usually displayed with voltage and current signal
levels that are input to the power analyzer.
The WT1800 provides not only this direct display
but also added a new computation range display
function to the external current sensor range.
This function allows you to display the primary
current range for the voltage output type current
sensor. It allows you to intuitively set a range that
is suited to the primary measurement signal
level.
A null function allows you to reset the offset
value to zero in the connected state. Previously,
all inputs could only be collectively set to ON or
OFF. With the WT1800, the null value for each
input can be set to ON, HOLD, or OFF.
In a motor evaluation test, the offset value for
only a particular input can be reset to zero. This
makes it possible to perform a more accurate
motor evaluation test.
Display the manual on the screen
Frequently used functions (keys) can be
performed without the instruction manual.
You may, however, want to use a new
function during evaluation. The WT1800
includes a built-in instruction manual on the
functions, so if a new operation is required,
you can read the explanation of the function
on the screen.
The data saving function of the WT Series is
capable of continuously saving data for a long
period of time. However, to check an irregular
event, data must be retrieved using spreadsheet
software.
The event trigger function allows you to set the
high and low limits and only trigger data that
falls into or out of that range to be saved.
Individual null function
Function to reset only a particular input signal to zero
* Co
mparison with Yokogawa’s previous model WT1600
Computation range display
Direct display of primary current values
User-defined event function
Capture only a particular event
Help function
Display the manual on the screen
A lot of information can be
displayed on a single screen
Data update rate changeable
All Data of 6-input, Single/Three-phase Devices can be Viewed on a
Single Screen
Important Information is Displayed in a Concentrated Format on
High Resolution 8.4-inch XGA Display
All Data of 6-input, Single/Three-phase Devices can be Viewed on a
Single Screen
Important Information is Displayed in a Concentrated Format on
High Resolution 8.4-inch XGA Display
Functions/Displays
Functions/Displays
Functions/Displays
urement
English help menu supports meas
Display example of
direct input range
Display example of
computation range
Innovative
function
Innovative
function
Innovative
function
Innovative
function
Innovative
function
Innovative
function
New function
New function
4