Comparison of Power Analyzer WT Series and PZ

Comparison of Power Analyzer WT Series and PZ

g

Comparison of the accuracy and range between the WT series and PZ

g

Comparison of the specifications and functions of the WT series and the PZ4000

0.2

0.1

0.05

Power measurement range [Hz]

DC

DC

10

10

100

100

1 k

1 k

10 k

10 k

100 k

100 k

1 M

1 M

Inverter (R&D and inspection)

Power consumption measurements of home appliances and OA equipment
Maintenance of plant equipment related to heavy electric machinery, power, and process automation

Industrial electric equipment
(Power supply, motor, air-conditioner, etc.)
Power measurements on production and
inspection lines

0.5 Hz WT210/WT230 basic power accuracy 0.2%

100 kHz

0.5 Hz

WT500 basic power accuracy 0.2%

100 kHz

0.1 Hz

PZ4000 basic power accuracy 0.125% 1 MHz

0.1 Hz

WT3000 basic power accuracy 0.06% 1 MHz

0.1 Hz

WT1800 basic power accuracy 0.15%

1 MHz

Battery

WT1800

WT3000

WT500

WT210/WT230

PZ4000

(opt.) : Optional

There are limitations on some specifications and functions. See the individual product catalogs for details.

0.1% of reading +0.025% of range
0.2% of reading +0.1% of range
DC, 0.1 Hz to 1 MHz
5 MHz (typical)
1, 2, 3, 4, or 1, 2, 3 +Motor module

30, 60, 120, 200, 300, 600, 1200, 2000 [Vpk]

5 A module:
0.1, 0.2, 0.4, 1, 2, 4, 10 [Apk] (5 A rms)
20 A module:
0.1, 0.2, 0.4, 1, 2, 4, 10 [Apk] (5 A rms)
1, 2, 4, 10, 20, 40, 100 [Apk] (20 A rms)

0.1, 0.2, 0.4, 1 [Vpk]

5% to 70% (peak range)

Voltage, current, active power, reactive power,
apparent power, power factor, phase angle,
frequency, peak voltage, peak current,
crest factor
Maximum 20
No

Yes

No
No
No
No

2 ch / module

Yes
Torque and rotational velocity input
(requires sensor input module 253771) (opt.)
No
Yes
Yes (4 functions)
6.4-inch VGA TFT color LCD
Yes (numeric, waveform, trend, X-Y,
bar graph, vector)
Maximum 5 MS/s
Yes
No

No

No
No
Yes

No

None, but acquisition memory has
100 kW/channel (up to 4 MW/channel
can be installed with /M3 option)

GP-IB, RS-232, Centronics, SCSI (/C7) (opt.)

Yes
Depends on waveform acquisition
length and calculations
FDD
top side (/B5) (opt.)

0.1% of reading +0.05% of range
0.05% of reading +0.1% of range
DC, 0.1 Hz to 1 MHz
5 MHz (typical)
1, 2, 3, 4, 5, 6
1.5, 3, 6, 10, 15, 30, 60, 100, 150, 300, 600,
1000 [V]

10 m, 20 m, 50 m, 100 m, 200 m, 500 m,
1, 2, 5 [A]
or, 1, 2, 5, 10, 20, 50 [A]

50 m, 100 m, 250 m, 500 m, 1, 2.5, 5, 10 [V]
(opt.)

1% to 110%

Voltage, current, active power, reactive power,
apparent power, power factor, phase angle,
frequency, peak voltage, peak current,
crest factor, integration (Wh, Ah, varh, Vah)
Maximum 300
Yes

Yes

Yes (user defined unction)
Yes
Yes
Yes

3 ch (up to 12 channels with option /FQ)

Yes
Torque, A / B / Z phase signal inputs (/MTR),
6 inputs, and motor evaluation (opt.)
Yes (2 inputs) (opt.)
No
Yes (20 functions)
8.4-inch XGA TFT color LCD
Yes (numeric, waveform, trend)
/G5 (opt.) or /G6 (opt.) (bar graph, vector)
Approximately 2 MS/s
(/G5) (opt.)
(/G6) (opt.)

No

No
No
(/DT) (opt.)

20 channels (/DA) (opt.)

Approximately 32 MB

GP-IB, USB, Ethernet
RGB output (/V1) (opt.)

Yes
50 m, 100 m, 200 m, 500 m, 1, 2, 5, 10,
20 [S]
USB
front side (/B5) (opt.)

0.02% of reading +0.04% of range
0.05% of reading +0.1% of range
DC, 0.1 Hz to 1 MHz
1 MHz
1, 2, 3, 4

15, 30, 60, 100, 150, 300, 600, 1000 [V]

5 m, 10 m, 20 m, 50 m, 0.1, 0.2, 0.5, 1, 2 [A]
or, 0.5, 1, 2, 5, 10, 20, 30 [A]

50 m, 100 m, 200 m, 500 m, 1, 2, 5, 10 [V]

1% to 130%

Voltage, current, active power, reactive power,
apparent power, power factor, phase angle,
frequency, peak voltage, peak current,
crest factor, integration (Wh, Ah, varh, Vah)
Maximum 300
Yes

Yes

Yes (user defined unction)
Yes
Yes
Yes

2 ch (up to 8 channels with option /FQ)

Yes
Torque, rotating speed input (/MTR),
4 inputs, and motor evaluation (opt.)
No
Yes (/G6) (opt.)
Yes (20 functions)
8.4-inch VGA TFT color LCD
Yes (numeric, waveform, trend)
/G6 (opt.) (bar graph, vector)
Approximately 200 kS/s
(/G6) (opt.)
No
(/G6) (opt.) (10 cycle / 50 Hz, 12 cycle / 60 Hz,
16 cycles (50 and 60 Hz)
(/FL) (opt.)
(/CC) (opt.)
(/DT) (opt.)

20 channels (/DA) (opt.)

Approximately 30 MB

GP-IB, RS-232 (/C2) (opt.)
USB (/C12) (opt.), VGA output (/V1) (opt.)
Ethernet (/C7) (opt.)
Yes
50 m, 100 m, 250 m, 500 m, 1, 2, 5, 10,
20 [S]
PC card interface, USB (/C5) (opt.)
front side (/B5) (opt.)

0.1% of reading +0.1% of range
0.1% of reading +0.1% of range
DC, 0.5 Hz to 100 kHz
100 kHz
1, 2, 3

15, 30, 60, 100, 150, 300, 600, 1000 [V]

500 m, 1, 2, 5, 10, 20, 40 [A]

50 m, 100 m, 200 m, 500 m, 1, 2, 5, 10 [V]
(opt.)

1% to 110%

Voltage, current, active power, reactive power,
apparent power, power factor, phase angle,
frequency, peak voltage, peak current,
crest factor, integration (Wh, Ah, varh, Vah)
Maximum 300
Yes

Yes

Yes (user defined unction)
Yes
Yes
Yes

2 ch (up to 6 channels with option /FQ)

Yes

No

No
No
Yes (8 functions)
5.7-inch VGA TFT color LCD
Yes (numeric, waveform, trend)
/G5 (opt.) (bar graph, vector)
Approximately 100 kS/s
(/G5) (opt.)
No

No

No
No
(/DT) (opt.)

No

Approximately 20 MB

USB, GP-IB (/C1) (opt.)
Ethernet (/C7) (opt.)
VGA output (/V1) (opt.)
Yes

100 m, 200 m, 500 m, 1, 2, 5 [S]

USB
No

0.1% of reading +0.1% of range
0.3% of reading +0.2% of range
DC, 0.5 Hz to 100 kHz
100 kHz
1 (WT210), 2 or 3 (WT230)

15, 30, 60, 100, 150, 300, 600 [V]

5 m, 10 m, 20 m, 50 m, 0.1, 0.2, 0.5, 1, 2, 5,
10, 20 [A] (WT210)
0.5, 1, 2, 5, 10, 20 [A] (WT230)

50 m, 100 m, 200 m [V] or 2.5, 5, 10 [V] (opt.)

1% to 130%

Voltage, current, active power, reactive power,
apparent power, power factor, phase angle,
frequency, peak voltage, peak current,
crest factor, integration (Wh, Ah)
Maximum 300
Yes

No

Yes
Yes
No
No

1 ch

Yes (WT230)

No

No
No
No
7-segment display

numeric (3 values)

Approximately 50 kS/s
(/HRM) (opt.)
No

No

No
No
No
4 channels (/DA4) (opt.) (WT210)
12 channels (/DA12) (opt.) (WT230)
Maximum 600 samples (WT210)
Maximum 300 samples (WT230)
* Only reading in the WT is possible.

GP-IB or RS-232 (WT210) (opt.)
GP-IB or RS-232 (WT230)

No

100 m, 250 m, 500 m, 1, 2, 5 [S]

No
No

Basic power accuracy (50/60 Hz)
DC power accuracy
Power frequency range
Voltage/Current frequency range
Input elements

Voltage range

Current range (direct input)

Current range (external sensor input)

Guaranteed accuracy range
for voltage and current

Main measurement parameters

Crest factor
MAX hold
Voltage RMS/MEAN
simultaneous measurement
Average active power
Active power integration (WP) (Wh)
Apparent power integration (WS) (VAh)
Reactive power integration (WQ) (varh)

Frequency measurement

Efficiency measurement

Motor evaluation

Auxiliary inputs
FFT spectral analysis
User-defined functions
Display

Display format

Sampling frequency
Harmonic measurement
Dual harmonic measurement
IEC standards-compliant
harmonic measurement
IEC flicker measurement
Cycle by cycle measurement
Delta calculation function

DA outputs

Storage
(internal memory for storing data)

Interfaces

Synchronous measurement

Data update interval

Removable storage
Built-in printer

Basic po

wer accurac

y [%]

Input

Measurement parameters

Display

Measurement /functions

Other fea

tures