beautypg.com

Model and suffix codes, Typical voltage/current connections, Accessory (sold separately) – Atec Yokogawa-WT1800 User Manual

Page 19: Rack mount, Exterior wt1800

background image

Current: 1000 Apk
Basic Accuracy:
±(0.05% of rdg + 30 μA)
Measurement Range:
DC to 300 kHz
Input/output ratio: 1500: 1

Current: 600 Apk
Basic Accuracy:
±(0.05% of rdg + 40 μA)
Measurement Range:
DC to 100 kHz
Input/output ratio: 1500: 1

Current: 200 Apk
Basic Accuracy:
±(0.05% of rdg + 30 μA)
Measurement Range:
DC to 500 kHz
Input/output ratio: 1000: 1

Current: 60 Apk
Basic Accuracy:
±(0.05% of rdg + 30 μA)
Measurement Range:
DC to 800 kHz
Input/output ratio: 600: 1

Measurement using current sensor

Current measurement using direct input terminal

Measurement using voltage input terminal

Power meter’s
voltage
input terminal

Power meter’s
current
input terminals

Connector

(B8200JQ)

Four load resistors*

(B8200JR)

connected inparallel

DC power supply
(±15 V, 1 A)

CT1000

Unit whose current
is to be measured

Unit whose current
is to be measured

Power meter’s voltage
input terminal

* A burden resistor is required for the CT1000, CT200, CT60, and 751574.

CT1000 AC/DC Current sensor

CT200 AC/DC Current sensor

CT60 AC/DC Current sensor

751574 Current transducer

g

Model and Suffix Codes

* The numbers in the "Description" column have the following meanings.
50 A: 50 A input element, 5 A: 5 A input element
Elements are inserted in the order shown starting on the left side on the back.
* GPIB, Ethernet and USB communication come standard.

g

Typical Voltage/Current Connections

Model Suffix

codes

Description

Measurement using clamp-on probe

Power meter’s current
direct input terminal

Current output type

WT1801

-01

50 A

-10

5 A

WT1801

-02

50 A

50 A

WT1802

-11

5 A

50 A

-20

5 A

5 A

-03

50 A

50 A

50 A

WT1803

-12

5 A

50 A

50 A

-21

5 A

5 A

50 A

WT1803

-30

5 A

5 A

5 A

-04

50 A

50 A

50 A

50 A

-13

5 A

50 A

50 A

50 A

WT1804

-22

5 A

5 A

50 A

50 A

-31

5 A

5 A

5 A

50 A

-40

5 A

5 A

5 A

5 A

-05

50 A

50 A

50 A

50 A

50 A

-14

5 A

50 A

50 A

50 A

50 A

WT1805

-23

5 A

5 A

50 A

50 A

50 A

-32

5 A

5 A

5 A

50 A

50 A

WT1805

-41

5 A

5 A

5 A

5 A

50 A

-50

5 A

5 A

5 A

5 A

5 A

-06

50 A

50 A

50 A

50 A

50 A

50 A

-15

5 A

50 A

50 A

50 A

50 A

50 A

-24

5 A

5 A

50 A

50 A

50 A

50 A

WT1806

-33

5 A

5 A

5 A

50 A

50 A

50 A

-42

5 A

5 A

5 A

5 A

50 A

50 A

-51

5 A

5 A

5 A

5 A

5 A

50 A

-60

5 A

5 A

5 A

5 A

5 A

5 A

-D

UL/CSA standard

-F

VDE standard

Power cord -R

AS standard

-Q

BS standard

-H

GB standard

Languages -HE

English menu

g

g

g

/EX1

External current sensor input for WT1801

p

/EX2

External current sensor input for WT1802

p

/EX3

External current sensor input for WT1803

p

/EX4

External current sensor input for WT1804

p

/EX5

External current sensor input for WT1805

p

/EX6

External current sensor input for WT1806

p

/B5

Built-in printer

p

Options

/G5

Harmonic Measurement

/G6

Simltaneous Dual Harmonic Measurement

/DT

Delta Computation

p

/FQ

Add-on Frequency Measurement

q

y

/V1

RGB output

p

/DA

20-channel DA Outputs

p

/MTR

Motor Evaluation Function

/AUX

Auxiliary Sensor Inputs

y

p

WT1800 Single input element

WT1800 2 input elements

WT1800 3 input elements

WT1800 4 input elements

WT1800 5 input elements

WT1800 6 input elements

Standard option

Additional option

Due to the nature of this product, it is possible to touch its metal parts. Therefore, there is a risk of electric shock,
so the product must be used with caution.
* Use these products with low-voltage circuits (42 V or less).

Model

Product

Description

751535-E4

Rack mounting kit

For EIA

751535-J4

Rack mounting kit

g

For JIS

Model/parts number

Product

Description

Order Q’ty

758917

Test read set

A set of 0.8 m long, red and black test leads

1

758922

Small alligator-clip

Rated at 300 V and used in a pair

1

758929

Large alligator-clip

Rated at 1000 V and used in a pair

1

758923

Safety terminal adapter

(spring-hold type) Two adapters to a set

1

758931

Safety terminal adapter

(screw-fastened type) Two adapters to a set
1.5 mm hex Wrench is attached

1

758924

Conversion adapter

BNC-banana-jack (female) adapter

1

366924

*

BNC-BNC cable

1 m

1

366925

*

BNC-BNC cable

2 m

1

701959

Safety mini-clip

Hook type, Two in a set

1

758921

Fork terminal adapter

Banana-fork adapter, Two adapters to a set

1

B9284LK

External sensor cable

Current sensor input connector, Length 0.5 m

1

B9316FX

Printer roll pager

Thermal paper, 10 meters (1 roll)

10

*

*

g

Accessory (sold separately)

g

Rack Mount

g

Exterior WT1800

Connection example

758921

701959

758917

758923

758931

758922

758929

758921

758923

758931

758917

751552

758921

Unit whose voltage
is to be measured

Unit whose voltage
is to be measured

unit: mm

13

426

13

32

427

43

177

20

32

Subject to change without notice.

[Ed : 01/b] Copyright ©2011

Printed in Japan, 102(KP)

YOKOGAWA METERS & INSTRUMENTS CORPORATION
Global Sales Dept.

/Phone: +81-42-534-1413 Facsimile: +81-42-534-1426

E-mail: [email protected]
YOKOGAWA CORPORATION OF AMERICA Phone: (1)-770-253-7000, Fax: (1)-770-254-0928
YOKOGAWA EUROPE B.V.

Phone: (31)-88-4641000, Fax: (31)-88-4641111

YOKOGAWA ENGINEERING ASIA PTE. LTD. Phone: (65)-62419933, Fax: (65)-62412606

Select one

Select one

Note: Adding input elements after initial product delivery will require rework at the factory. Please

choose your models and configurations carefully, and inquire with your sales representative if you
have any questions

Standard accessories

Power cord, Rubber feet, current input protective cover, User’s manual, expanded user’s manual,
communication interface user’s manual, printer roll paper (provided only with /B5), connector
(provided only with /DA) Safety terminal adapter 758931 (provided two adapters in a set times
input element number)

O Yokogawa's electrical products are developed and produced in facilities that

have received ISO14001 approval.

O In order to protect the global environment, Yokogawa's electrical products are

designed in accordance with Yokogawa's Environmentally Friendly Product
Design Guidelines and Product Design Assessment Criteria.

Yokogawa's Approach to Preserving the Global Environment

NOTICE

O Before operating the product, read the user's manual thoroughly for proper

and safe operation.

O If this product is for use with a system requiring safeguards that directly
involve personnel safety, please contact the Yokogawa sales offices.