Atec Flexim-G601 User Manual
Page 20
20
TSFLUXUS_G601V1-5-1US_Lus, 2014-02-25
FLUXUS® G601
Technical Specification
Lamb Wave Transducers
technical type
GRM1NC3
GRP1NC3
GRQ1NC3
order code
GLM-NNNNL
GLP-NNNNL
GLQ-NNNNL
transducer frequency
MHz 1
2
4
medium pressure
1
min. extended
psi
-
-
-
min.
psi
metal pipe:
145 (d > 2.4 in)
73 (d < 2.4 in)
plastic pipe: 15
metal pipe:
145 (d > 1.4 in)
73 (d < 1.4 in)
plastic pipe: 15
metal pipe:
145 (d > 0.59 in)
73 (d < 0.59 in)
plastic pipe: 15
inner pipe diameter d
2
min. extended
in
1.2
0.59
0.28
min. recommended
in
1.6
0.79
0.39
max. recommended
in
3.5
2
0.87
max. extended
in
5.9
2.8
1.4
pipe wall thickness
min.
in
0.08
0.04
0.02
max.
in
0.2
0.12
0.04
material
housing
PPSU with stainless steel
cap 304
PPSU with stainless steel
cap 304
PPSU with stainless steel
cap 304
contact surface
PPSU
PPSU
PPSU
degree of protection
NEMA 4
NEMA 4
NEMA 4
transducer cable
type
1699
1699
1699
length
ft
13
13
9
dimensions
length l
in
2.91
2.91
1.65
width b
in
1.26
1.26
0.87
height h
in
1.59
1.59
1
dimensional drawing
ambient temperature
min.
°F
-40
-40
-40
max.
°F
+338
+338
+338
temperature
compensation
x
x
x
remark
on request
1
depending on application, typical absolute value for natural gas, nitrogen, compressed air
2
Lamb wave transducer:
typical values for natural gas, nitrogen, oxygen, pipe diameters for other gases on request
pipe diameter min. recommended/max. recommended: in reflect arrangement and for a flow velocity of 49 ft/s
pipe diameter max. extended: in diagonal arrangement and for a flow velocity of 82 ft/s
l
h
b
l
h
b
l
h
b