Technical data – Atec Flexim-G601 User Manual
Page 16
16
TSFLUXUS_G601V1-5-1US_Lus, 2014-02-25
FLUXUS® G601
Technical Specification
Technical Data
Shear Wave Transducers
technical type
GDG1NZ7
GDK1NZ7
order code
GSG-NNNNL
GSK-NNNNL
transducer frequency
MHz 0.2
0.5
medium pressure
1
min. extended
psi
metal pipe: 290
metal pipe: 290
min.
psi
metal pipe: 435
plastic pipe: 15
metal pipe: 435
plastic pipe: 15
inner pipe diameter d
2
min. extended
in
9.8
2.8
min. recommended
in
15
3.1
max. recommended
in
31.9
19.7
max. extended
in
43.3
28.3
pipe wall thickness
min.
in
0.55
0.2
max.
in
-
-
material
housing
PEEK with stainless steel
cap 304
PEEK with stainless steel
cap 304
contact surface
PEEK
PEEK
degree of protection
NEMA 6
NEMA 6
transducer cable
type
1699
1699
length
ft
16
16
dimensions
length l
in
5.1
4.98
width b
in
2.01
2.01
height h
in
2.64
2.66
dimensional drawing
ambient temperature
min.
°F
-40
-40
max.
°F
+266
+266
temperature
compensation
x
x
1
depending on application, typical absolute value for natural gas, nitrogen, compressed air
2
shear wave transducer:
typical values for natural gas, nitrogen, oxygen, pipe diameters for other gases on request
pipe diameter min. recommended/max. recommended/max. extended: in diagonal arrangement and for a flow velocity of 49 ft/s
l
h
b
l
h
b