Atec Flexim-G601 User Manual
Page 17
TSFLUXUS_G601V1-5-1US_Lus, 2014-02-25
17
Technical Specification
FLUXUS® G601
Shear Wave Transducers
technical type
GDM1NZ7
GDP1NZ7
GDQ1NZ7
order code
GSM-NNNNL
GSP-NNNNL
GSQ-NNNNL
transducer frequency
MHz 1
2
4
medium pressure
1
min. extended
psi
metal pipe: 290
metal pipe: 290
metal pipe: 290
min.
psi
metal pipe: 435
plastic pipe: 15
metal pipe: 435
plastic pipe: 15
metal pipe: 435
plastic pipe: 15
inner pipe diameter d
2
min. extended
in
1.2
0.59
0.24
min. recommended
in
1.6
0.79
0.39
max. recommended
in
3.1
1.6
0.79
max. extended
in
4.7
2.4
1.2
pipe wall thickness
min.
in
0.1
0.06
0.04
max.
in
-
-
-
material
housing
stainless steel 304
stainless steel 304
stainless steel 304
contact surface
PEEK
PEEK
PEEK
degree of protection
NEMA 6
NEMA 6
NEMA 6
transducer cable
type
1699
1699
1699
length
ft
13
13
9
dimensions
length l
in
2.36
2.36
1.67
width b
in
1.18
1.18
0.71
height h
in
1.32
1.32
0.85
dimensional drawing
ambient temperature
min.
°F
-40
-40
-40
max.
°F
+266
+266
+266
temperature
compensation
x
x
x
remark
on request
1
depending on application, typical absolute value for natural gas, nitrogen, compressed air
2
shear wave transducer:
typical values for natural gas, nitrogen, oxygen, pipe diameters for other gases on request
pipe diameter min. recommended/max. recommended/max. extended: in diagonal arrangement and for a
flow velocity of 49 ft/s
h
b
l
h
b
l
h
b
l