Atec Anritsu-MT2720T User Manual
Page 2
PN: 11410-00646 Rev. H
MS2720T TDS
Spectrum Analyzer Specifications
Spectrum Master™ MS2720T
Spectrum Analyzer
All specifications and characteristics apply to Revision 2 instruments under the following conditions, unless otherwise stated: 1) After 5 minutes of warm-up time, where the
instrument is left in the ON state; 2) Apply when using internal reference and performance sweep mode; 3) Subject to change without notice; 4) Typical performance is the
measured performance of an average unit; 5) Recommended calibration cycle is 12 months.
Measurements
Smart Measurements
Field Strength (dBm/m
2
, dBW/m
2
, V/m, A/m, Watt/m
2
, Watt/cm
2
, or dBmV/m)
Occupied Bandwidth (measures 99 % to 1 % power channel of a signal)
Channel Power (measures the total power in a specified bandwidth)
ACPR (adjacent channel power ratio)
AM/FM/SSB Demodulation (AM, wide/narrow FM, upper/lower SSB), (audio out only)
C/I (carrier-to-interference ratio)
Emission Mask (recall limit lines as emission mask)
Setup Parameters
Frequency
Center/Start/Stop, Span, Frequency Step, Frequency Offset, Signal Standard, Channel #
Amplitude
Reference Level (RL), Scale, Attenuation Auto/Level, RL Offset, Pre-Amp On/Off, Detection
Span
Span, Span Up/Down (1-2-5), Full Span, Zero Span, Last Span
Bandwidth
RBW, Auto RBW, VBW, Auto VBW, RBW/VBW Ratio, Span/RBW Ratio
Sweep Functions
Sweep
Single/Continuous, Manual Trigger, Reset, Detection, Minimum Sweep Time, Trigger Type
Sweep Mode
Fast (100x Performance), Performance, No FFT, Burst Detect (1000x Fast in 15 MHz span)
Detection
Peak, RMS/Avg, Negative, Sample, Quasi-peak
Triggers
Free Run, External, Video, Manual, IF Power
Trigger Position
Delay, Level, Slope, Hysteresis, Holdoff, Force Trigger Once
Trace Functions
Traces
Up to three Traces (A, B, C), View/Blank, Write/Hold, Trace A/B/C Operations
Trace A Operations
Normal, Max Hold, Min Hold, Average, # of Averages, (always the live trace)
Trace B Operations
A → B, B ← → C, Max Hold, Min Hold
Trace C Operations
A → C, B ← → C, Max Hold, Min Hold, A – B → C, B – A → C, Relative Reference (dB), Scale
Marker Functions
Markers
Markers 1-6 each with a Delta Marker, or Marker 1 Reference with Six Delta Markers,
Marker Table (On/Off/Large), All Markers Off
Marker Types
Style (Fixed/Tracking), Noise Marker, Frequency Counter Marker
Marker Auto-Position
Peak Search, Next Peak (Right/Left), Peak Threshold %, Set Marker to Channel,
Marker Frequency to Center, Delta Marker to Span, Marker to Reference Level
Marker Table
1-6 markers frequency and amplitude, plus delta markers frequency offset and amplitude
Limit Line Functions
Limit Lines
Upper/Lower, On/Off, Edit, Move, Envelope, Advanced, Limit Alarm, Default Limit
Limit Line Edit
Frequency, Amplitude, Add Point, Add Vertical, Delete Point, Next Point Left/Right
Limit Line Move
To Current Center Frequency, By dB or Hz, To Marker 1, Offset from Marker 1
Limit Line Envelope
Create Envelope, Update Amplitude, Number of Points (41), Offset, Shape Square/Slope
Limit Line Advanced
Type (Absolute/Relative), Mirror, Save/Recall
Frequency
Frequency Range
(usable to 0 Hz)
MS2720T-0709
9 kHz to 9 GHz
MS2720T-0713
9 kHz to 13 GHz
MS2720T-0720
9 kHz to 20 GHz
MS2720T-0732
9 kHz to 32 GHz
MS2720T-0743
9 kHz to 43 GHz
Tuning Resolution
1 Hz
Frequency Reference
Aging: ± 1.0 x 10
–6
per 10 years
Accuracy: ± 0.3 x 10
–6
(25 °C ± 25 °C) plus aging
(see Options 1 and 31 for improved frequency reference aging and accuracy)
Auto-sensing External Frequency
Reference (MHz)
1, 1.2288, 1.544, 2.048, 2.4576, 4.8, 4.9152, 5, 9.8304, 10, 13, 19.6608
Sweep Time
10 µs to 600 s in zero span
Sweep Time Accuracy
± 2 % in zero span
Bandwidth
Resolution Bandwidth (RBW)
1 Hz to 10 MHz in 1–3 sequence ± 10 % (–3 dB bandwidth)
Video Bandwidth (VBW)
1 Hz to 10 MHz in 1–3 sequence (–3 dB bandwidth)
RBW with Quasi-Peak Detection
200 Hz, 9 kHz, 120 kHz (–6 dB bandwidth)
VBW with Quasi-Peak Detection
Auto VBW is On, RBW/VBW = 1
VBW/Average Type
Linear/Log