Wimax fixed/mobile measurements (option 885) – Atec Anritsu-MT2720T User Manual
Page 15
Spectrum Master™ MS2720T
Spectrum Analyzer Specifications
MS2720T TDS
PN: 11410-00646 Rev. H
15 of 24
WiMAX Fixed/Mobile Measurements (Option 885)
WiMAX Fixed Measurements
Setup Parameters
Bandwidth (MHz)
1.25, 1.50, 2.50, 3.50, 5.00, 5.50, 6.00, 7.00, 10.00
Cyclic Prefix Ratio (CP)
1/4, 1/8, 1/16, 1/32
Span (MHz)
5, 10, 15, 20
Frame Length (ms)
2.5, 5.0, 10.0
Frequency
Center, Signal Standard, Channel #, Closest Channel, Decrement/Increment Channel
Amplitude
Scale/Division, Power Offset, Auto Range, Adjust Range
Sweep
Single/Continuous, Trigger Sweep
Save/Recall
Setup, Measurement, Screen Shot (save only), to Internal/External Memory
Measurement Summary Screens
Overall Measurements, RF Measurements, Modulation Measurements
WiMAX Fixed RF Measurements
(temperature range 15 °C to 35 °C)
RF Channel Power Accuracy
± 1.5 dB, ± 1.0 dB typical, (RF input –50 dBm to +20 dBm)
WiMAX Fixed Demodulation Measurements
(temperature range 15 °C to 35 °C)
Frequency Error
0.07 x 10
–6
plus time base error, 99 % confidence level
Residual EVM (rms)
3 % typical, 3.5 % maximum (RF Input –50 dBm to +20 dBm)
RF
Demodulation
Over-the-Air (OTA)
Pass/Fail
Channel Spectrum
Channel Power
Occupied Bandwidth
Power vs. Time
Channel Power
Preamble Power
Data Burst Power
Crest Factor
ACPR
RF Summary
Constellation
RCE (RMS/Peak)
EVM (RMS/Peak)
Frequency Error
Carrier Frequency
Base Station ID
Spectral Flatness
Adjacent Subcarrier Flatness
EVM vs. Subcarrier/Symbol
RCE
EVM
Frequency Error
Carrier Frequency
Base Station ID
Sector ID (Mobile)
Modulation Summary
There are no additional OTA
Measurements
RF and Demodulation Measurements
can be made OTA
View Pass/Fail Limits
All, RF, Modulation
Available Measurements
Channel Power
Occupied Bandwidth
Burst Power
Preamble Power
Crest Factor
Frequency Error
Carrier Frequency
EVM
RCE
Base Station ID