Internal real-time complex digital I/Q filters (included with Option 653 )

Factory channel correction (256 taps)
Corrects the linear phase and amplitude response of the baseband IQ and RF outputs of the signal generator using factory calibration

arrays (default mode is off).

RF amplitude flatness (120 MHz)

± 0.2 dB measured

RF phase flatness (120 MHz)

± 2 degrees measured

User channel correction (256 taps)
Automated routine uses USB power sensor to correct for linear phase and amplitude response of DUT (equalizer). See User Guide for

more details.
Max RF amplitude flatness correction

± 15 dB

Max RF phase flatness correction

± 20 degrees

Equalization filter (256 taps)
User can download and apply inverse or custom phase and amplitude response coefficients from tools such as MATLAB, 89600 VSA,

or SystemVue to correct for linear errors of DUT/system. See User Guide for more details.

Baseband generator (Options 653 and 655)

Channels

2 [I and Q]

Resolution

16 bits [1/65,536]

Sample rate

Option 653

100 Sa/s to 75 MSa/s

Option 653 and 655

100 Sa/s to 150 MSa/s

RF (I+Q) bandwidth

Option 653

60 MHz, nominal

Option 653 and 655

120 MHz, nominal

Interpolated DAC rate

800 MHz (waveforms only need OSR = 1.25 )

Frequency offset range

± 60 MHz

Digital sweep modes

In list sweep mode each point in the list can have independent waveforms (N5172B)

along with user definable frequencies and amplitudes; see the Amplitude and Frequency

Specifications sections for more detail.

Waveform switching speed

1

SCPI mode

≤ 5 ms, measured (standard)
≤ 1.2 ms, measured (Option UNZ)

List/step sweep mode

≤ 5 ms, measured (standard)
≤ 900 us, measured (Option UNZ)

Waveform transfer rates

(measured, no markers)

FTP LAN to internal SSD

10.7 MB/sec or 2.67 Msa/sec

Internal SSD to FTP LAN

7.7 MB/sec 1.92 Msa/sec

FTP LAN to BBG

8.2 MB/sec or 2.05 Msa/sec

FTP LAN to BBG encrypted

4 MB/sec or 1 Msa/sec

USB to BBG

19 MB/sec or 4.75 Msa/sec

BBG to USB

1.2 MB/sec or 300 Ksa/sec

Internal SSD to BBG

48 MB/sec or 12 Msa/sec

BBG to internal SSD

1.2 MB/sec or 300 Ksa/sec

SD card to BBG (Option 006)
BBG to SD card (Option 006)

845 KB/sec or 211 Ksa/sec

1. SCPI mode switching speed applies when waveforms are pre-loaded in list sweep and sample rate ≥ 10 MSa/s.