beautypg.com

Atec Agilent-N5171B User Manual

Page 12

background image

12

Residual FM (CW mode, 300 Hz to 3 kHz BW, CCITT, rms)

5 MHz to 6 GHz

< N x 2 Hz (measured) (see N value in frequency band table)

Harmonics (CW mode)

Range

Standard < +4 dBm

Option 1EA < +12 dBm

9 kHz to 3 GHz

< –35 dBc

< –30 dBc

> 3 to 4 GHz

< –35 dBc, typical

< –35 dBc, typical

> 4 to 6 GHz

< –53 dBc, typical

< –40 dBc, typical

Nonharmonics (CW mode)

Range

> 10 KHz offset

Standard (dBc)

9 kHz to < 5 MHz

–65, nominal

5 to < 250 MHz

–75

250 to < 750 MHz

–75

750 MHz to < 1.5 GHz

–72

1.5 to < 3.0 GHz

–66

3 to 6 GHz

–60

Subharmonics (CW mode)

9 kHz to 1.5 GHz

None

> 1.5 to 3 GHz

–77 dBc

> 3 to 6 GHz

–74 dBc

Jitter

1

Carrier frequency

SONET/SDH data rate rms jitter BW

μUI rms, measured Seconds, typical

155 MHz

155 MB/s

100 Hz to 1.5 MHz

140

0.9 ps

622 MHz

622 MB/s

1 KHz to 5 MHz

67

0.11 ps

2.488 GHz

2488 MB/s

5 kHz to 20 MHz

271

0.11 ps

Phase coherence (Option 012)

LO input frequency range

250 MHz to 6 GHz, nominal

LO input power range

0 to +12 dBm, nominal

LO output frequency range

250 MHz to 6 GHz, nominal

LO output power range

0 to +12 dBm, nominal

1. Calculated from phase noise performance in CW mode at +10 dBm. For other frequencies, data rates, or bandwidths, please consult your sales

representative.